7. Starting Procedure

Before use, read, pay attention to and carefully
keep both the operating and safety instructions.
Ensure a specialist.connects the compressed air
supply to the riveting tool
7.1 Installation of the spent mandrel
Screw the spent mandrel container on to the tool
by turning it clockwise.
7.2 Selection and exchange of nosepieces
ttention: Always use a nosepiece
corresponding to the blind rivet size
(selection according to table point 6.)
Exchanging nosepieces
– Disconnect the tool from the compressed air
– Unscrew the nosepiece from the tool head
– Screw in and tighten the replacement nose-
piece.

7.3 Setting a blind rivet

– Connect the tool to the compressed air.
– Insert the blind rivet into the nosepiece and
place the rivet into the workpiece
– Press the yellow trigger until mandrel breaks.
– Release the yellow trigger
– The mandrel is automatically transported to
the mandrel container (see point 7.5)
7.4 Suction and holding of a blind rivet
This feature allows the blind rivet to be held
in the tool nosepiece for vertical, downwards
riveting.
– Open the ON/OFF valve N° 88 in the tool
head by pushing it to the right or left stop
with a pin (e.g. a mandrel) to enable the
suction feature.
– After Closing the hand on the pistol grip push
slider N° 86 upwards to stop to switch on the
suction. Pushing slider N° 86 downwards will
switch off the suction.
– Pushing back the ON/OFF valve N° 88 will
permanently disable the suction feature.

7.5 Emptying the mandrel container

– The mandrel container must be emptied
regularly; Overfilling causes the tool to mal-
function.
– Unscrew the container counter-clockwise and
dispose of spent mandrels according to valid
recycling procedures.
– Screw the spent mandrel container back on to
the tool.
14

8. Maintenance and Care

The complete jaw assembly must be regularly
maintained.

8.1 Lubricating the jaws

– Disconnect the tool from the compressed air
– Screw off steel head N° 24
– Dip the complete jaw housing into oil as far
as N° 17 O-ring, or spray oil on Jaws N° 15
– Reassemble in reverse order.
8.2 Exchanging jaws
– Disconnect the tool from the compressed air
– Screw off steel head N° 24/N° 110
– Screw off jaw housing N° 16/N° 111
– Remove jaws N° 15
– Clean jaw housing and grease friction surfaces
– Insert new jaws from the front (grease will
hold in position)
– ReasseHydraulic fluid refill
8.3 Hydraulic fluid refill
– Disconnect the tool from the compressed air
– Screw off steel head N° 24
– Unscrew and remove fluid refill screw N° 30
c/w sealing ring N° 31, using a T20 Torx
screwdriver
– Screw on included oil filling container
with cover
– Reconnect the tool to the air pressure and
depress yellow trigger once. Disconnect the
tool from compressed air
– Empty old oil from the oil container.
– Fill oil container with new hydraulic fluid,
up to mark
– Move traction rod back and forth carefully
several times by hand until oil escapes
bubble-free. Push traction rod fully back up
to stop and leave in this position.
– Remove oil filling container and screw back
sealing ring and refill screw
– Reconnect the tool to compressed air.
– Carefully loosen oil filling screw by 2 revs;
Traction rod will move slowly up to forward
stop. Wipe away spilt oil.
– Retighten oil filling screw
– Screw on steel head N° 24