Sennheiser ew 100 G2 Notice D'emploi page 68

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Changing the microphone head
First remove the batteries/accupack as described above and leave the
radiomicrophone open.
Unscrew the sound inlet basket.
Loosen the screw and put it to one side.
Gently ease the capsule out of the contacts and then pull it out of the hou-
sing as shown. Do not touch the contacts and the diaphragm!
Insert the new capsule.
Secure the capsule by tightening the screw.
Note:
The screw mechanically secures the microphone capsule. If the screw is
missing, malfunctions may occur during tough use.
Put on the sound inlet basket and identification ring supplied with the
new microphone head (NB: do NOT use the old basket, as the different
heads use slightly differing internal foam) and screw it tight.
Insert the batteries/accupack.
Close the radiomicrophone and put it into operation.
Note:
Microphone capsule, sound inlet basket and foam insert form an acoustic
unit and must therefore always be exchanged all together. Each micro-
phone head comes with a color-coded identification ring to distinguish
different microphone heads from each other (green = MD 835, blue = MD
845, red = ME 865).