Monacor PA-1200C Mode D'emploi page 13

Masquer les pouces Voir aussi pour PA-1200C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5) The relay contacts are change-over contacts and
can be charged with 24 V /500 mA as a maximum.
Connect the contacts REL 1 to REL 3 to the units to
be controlled.
The connections CHIME A, CHIME B, and
CHIME C are connected in parallel to the buttons of
the same names (2 – 4) on the front panel. For
remote-controlling, connect corresponding mo men -
tary pushbuttons to these connections.
If the timer insertion is not operated in combination
with the digital message insertion PA-1120DM, the
installation is terminated. Close the amplifier or the
basic unit with the housing cover.
If the timer is operated in combination with the digital
message insertion PA-1120DM, the following steps
have to be made additionally:
6) Install the digital message insertion PA-1120DM ac -
cording to the operating instructions supplied with it.
7) Make the following setting at the insertion PA-
1120DM. Place the jumper SEL 4 on the pins 1 and
2 (see operating instructions PA-1120DM, chap ter 4,
item 4).
8) Two 10-pole cables are supplied with the insertion
PA-1120DM. Put the cable with one inline jack at
each end into the pin housing CN4-1 of the PA-
1120DM (see operating instructions PA-1120DM,
chapter 3, item 6).
Put the second supplied cable into the inline jack
of the first cable and connect the stripped core ends
to the terminal strip CON 3 (t) according to fig. 5.
ST
M6
M5
M4
M3
M2
M1

Connection of the terminal strip CON 3
(for calling announcements of the PA-1120DM)
The four cores of the colours white, grey, blue, and vio-
let are not connected and have to be insulated.
9) Close the basic unit with the housing cover.
5 Operation
Switch on the amplifier or the basic unit with the mains
switch. The display (1) of the timer shortly indicates
"MONACOR PA-1200C" and the software version.
Then the date (a) with the weekday (e) ["1" = Monday,
"7" = Sunday], the time (d), and the timer status (b) are
indicated. If the timer is set into operation for the first
time, the date and the time have to be updated (see
chapter 5.2.5 "Menu item SET DATE & TIME").
5.1 Chime
It is possible to trigger a chime with the buttons CHIME
A (2), CHIME B (3), and CHIME C (4).
CHIME A – one-sound chime
CHIME B – two-sound chime
CHIME C – three-sound chime
CON 3
Adjust the desired volume with the volume control
LEVEL (6).
Note: When pressing these buttons, at the same time
also announcements of the digital message insertion
PA-1120DM can be started and relays can be acti-
vated if settings were made according to chapter 5.2.6
"Menu item SET PUSH-BUTTONS".
5.2 Making settings and
programming switch ing times
To change the programming mode, keep the button
PROG (5) pressed for 3 seconds until the display
switches over:
MENU
 CHIME ON/OFF
In this mode it is possible to programme switching
times, to change or cancel programmed switching
times, and to make basic settings (e. g. date, hour).
All settings are permanently memorized and are kept
even if the power supply is interrupted.
Important! If momentary pushbuttons are connect -
ed to the connection PCB (fig. 4), they
must not be pressed during a program-
ming procedure as they are connected
in parallel to the buttons CHIME (2 – 4)
on the front panel.
5.2.1 Menu item CHIME ON/OFF
Activating or deactivating the timer
Under this menu item all programming steps can be
activated or deactivated.
1) After switching on the programming mode, the item
 CHIME ON/OFF is selected. If another menu item
was selected in the meantime, go to this menu item
with the button UP (2) or DOWN (3).
2) Call the submenu for the activation/deactivation
with the button ENTER (4). Activate the timer with
the button DOWN (display  ON) or deactivate it with
the button UP (display  OFF).
3) Define the setting with the button ENTER. Then the
display shows:
CHIME=ON
<PRESS ENTER>
To confirm press the button ENTER again.
4) To quit the programming mode, select the menu
item  EXIT with the button DOWN and confirm with
the button ENTER. The display shows time and
date again.
In the standard mode the display indicates the ad-
justed timer status (b) behind the time.
5.2.2 Menu item NEW SETTINGS
Programming new switching times
To programme a new switching time, go with the button
UP (2) or DOWN (3) to the menu item
MENU
 NEW SETTINGS
and call the first submenu for the starting time with
the button ENTER (4).
CHIME=OFF
or
<PRESS ENTER>
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

17.1160

Table des Matières