BOLA
Cordless Pumps for Acids and Caustig Solutions
Objection
The pump does not start
to work.
The pump does not suck.
7. Waste Disposal
BOLA Cordless Pumps for Acids and Caustic Solutions as well as their packing are made of recyclable materials. Please
take further information on the materials used from the following specifications:
8. Specification
BOLA Cordless Pumps for Acids and Caustic Solutions
Cat.-No.
Length of
suction pipe
G 870-01 400 mm
G 870-11 600 mm
9. Registered Trademarks
Hastelloy® is a registered trademark of Haynes International, Inc.
Reason and help
»
The batteries/accumulators are empty.
Check whether the accumulators have to be charged and exchange them against new
ones if necessary.
»
The batteries/accumulators are not inserted correctly.
Check the direction of the poles. The positive poles have to be in direction of the
opening of the battery housing (1).
»
The pump shaft is stuck. Rinse the pump with hot water.
»
The pump has sucked in solid particles. The pump is not suitable for liquids which
contain solids. Rinse the pump with hot water.
»
The charge state of the batteries is too low.
Check your accumulators and charge or exchange them if necessary.
»
The suction pipe is not deep enough immersed in the liquid.
Immerse the suction pipe for at least 15 mm.
»
The product is too viscous.
The pump is suitable only for watery products.
Suction
Flow rate Temperature
pipe O.D.
approx.
Max.
25 mm
6 Liter
pro
Minute
Weight
resistance
+ 5 °C bis
approx.
+ 60 °C
500 g
approx.
600 g
Materials
Power Supply
Polypropy-
Two
lene
accumulators,
Hastelloy®,
Type Mono
PTFE
1,5 V
8