Connecting the cooktop to the power supply
The nameplate label is located on the underside of the cooktop, on the right hand side. See Fig.
5 below.
If the appliance is to be completely enclosed in a cabinet, feed the appliance cable through the
opening in the cabinet.
1
Disconnect the power supply.
2
Remove the junction box cover.
3
Connect the cooktop cable to the junction box through the CSA or UL-listed conduit connector.
4
Connect the two black wires together with twist-on connectors.
5
Connect the two red wires together with twist-on connectors.
6
Connect electrical connection according to local codes and ordinances.
If local codes PERMIT connecting the cabinet-grounding connector to the neutral (white)
wire in the junction box:
7a
Connect the green cooktop cable wire to the neutral (white) wire in the junction box (Fig. 3).
8a
Replace the junction box cover.
OR If local codes DO NOT PERMIT connecting the cabinet-grounding connector to the
neutral (white) wire in the junction box:
7b
Terminate the neutral (white) wire in the junction box (Fig. 3).
8b
Connect the green grounding cooktop cable wire to a grounded wire in the junction box.
9b
Replace the junction box cover.
OR If connecting to a four-wire electrical system:
7c
Terminate the neutral (white) wire in the junction box (Fig. 4).
8c
Connect the green cooktop cable wire to the green grounding wire in the junction box (Fig. 4).
9c
Replace the junction box cover.
3-wire cable from
power supply
Junction box
Red wires
White
wire
Green & yellow
wire
Fig. 3 Electrical connection to
a three-wire electrical system
Black wires
CSA or UL-listed
conduit connector
to appliance
Installation instructions
4-wire cable from
power supply
Junction box
Red wires
Green & yellow
wires
Fig. 4 Electrical connection to a
four-wire electrical system
Fig. 5 Location of nameplate label
13
White wire
Black wires
CSA or UL-listed
conduit connector
to appliance
US
CA

Publicité