Control Unit Function Setup; Association And Disassociation Of E.sybox And Control Unit - DAB PUMPS e.sybox Instructions Pour L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
ENGLISH
No action
in
(2)
=10, 11, 12,
13 Kiwa function
(low input pres-
sure signal)
No action
PR=0
Remote pres-
sure sensor
disabled
No action
PR=1
Use of remote
pressure sensor
Tab.5 Triggering of safety mode
The activation of the function relating to this box + any other function in
(1)
safety mode triggers a system stop. In this case, the system displays the
highest priority stoppage cause.
The numbers separated by commas indicate the possible setting values
(2)
for the function concerned
Instead, as regards the control unit, if there is a loss of communication it
lights relay 1 depending on the settings of O1 (see tab 20), considering the
lack of communication an error condition.

5.1.4 - Control unit function setup

The default value of all the inputs and the remote pressure sensor is DISA-
BLE, so before they can be used, they must be activated by the user; see
point 7.6.15 - Setup of auxiliary digital inputs IN1, IN2, IN3, IN4, pressure
sensor point 7.5.6 - PR: Remote pressure sensor.
The outputs are enabled by default, see output functions point 7.6.16 -
Setup of outputs OUT1, OUT2.
If no control unit has been associated, the input, output and remote pres-
sure sensor functions are ignored and have no effect, regardless of their
setups.
The control unit parameters (inputs, outputs and pressure sensors) can be
set even if the connection is down or even not made.
7 5
System in
No action
System in
stop status F4
stop status
No action
No action
No action
No action
Remote set-
Setpoint
on remote
point ignored
sensor
If the control unit is associated (it is included in the e.sybox's wireless net-
work) but is not present or not visible due to problems, when the param-
(1)
eters related to these functions are set at a value other than disable they
blink to indicate that they will not be able to fulfil their functions.

5.1.5 - Association and disassociation of e.sybox and control unit

The procedure for associating a control unit to an e.sybox is the same as
for associating an e.sybox:
locate the AS page of the installer menu and hold down the "+" key for 5
sec., until the blue LED blinks (whether the e.sybox is stand-alone or in a
group). After this, press the ► key for 5 sec. until the blue communication
LED starts to blink. As soon as the connection has been established, the
LED becomes steady and the e.sylink symbol appears on the AS page of
the e.sybox.
The procedure for disassociating the e.sylink is the same as for the e.sy-
box: locate the AS page of the installer menu and hold down the "-" key for
5 sec; this will eliminate all the wireless connections present.