INSTALLATION
GAS HOOK-UP
NATURAL GAS HOOK-UP (continued)
To hook-up the fittings supplied with the side burner, assemble as shown in Fig.06. Use joint compound on
male threads only.
Do not use joint compound on the flare end of the 1/2" NPT to 3/8"
flare adapter. Ensure that the regulator arrow points in the direction of
gas flow-towards the unit, away from the supply.
Do not forget to place the installer-supplied gas valve in an accessible
location.
LP GAS HOOK-UP
CONNECTION: 1/2" NPT female with 3/8" flare adapter
(included). Use 90º elbow 1/2" NPT with 3/8" flare
(P/N 212394) for side mount models only when installing on the cart.
Use sealer on 1/2" NPT threads only.
OPERATING PRESSURE: 11.0" W.C. side burner uses the LP regulator
from adjoining grill.
SUPPLY PRESSURE: 12" to 14" W.C.
Apply joint compound to the threaded end of the side burner gas
inlet and tighten the adapter to the pipe. Assemble the 24" and
30" hoses to the 3/8" flare tee, as shown in Fig.07. Tighten the regulator hose to the remaining fitting of the 3/8"
flare tee.
LP TANK REQUIREMENTS
A dented or rusty LP gas cylinder may be hazardous and should be
n
checked by your LP supplier. Never use a cylinder with a damaged
valve.
The LP gas cylinder must be constructed and marked in
n
accordance with the specifications for LP gas cylinders of the U.S.
Department of Transportation (DOT ) and designed for use with a
Type 1 system only.
Do not change the regulator/hose assembly from that
n
supplied with the unit or attempt to use a Type 1 equipped
regulator/hose assembly with a standard 510 POL tank/valve as-
sembly. The cylinder must be provided with a shut-off valve termi-
nating in an LP gas supply cylinder valve outlet
applicable, for connection Type 1.
If the appliance is stored indoors, the cylinder must be disconnect-
n
ed and removed from the appliance.
Cylinders must be stored outdoors in a well ventilated area out of the reach of children.
n
Gas cylinder supply must be turned off when not in use.
n
specified, as
Bottom of
131 &132 Burner
Open Top
Manifold
1/2" Coupling
1/2" NPT x 2.0"
Nipple
Regulator
1/2" NPT x 2.0"
Nipple
1/2" NPT to 3/8"
Flare Adapter
To Gas Supply
FIG. 06 Natural Gas
FIG. 07 LP Gas
13