5.
Trouble shooting
Fault
The indicator lamp
does not light up
Water temperature
not as required
Too little/no water
Water lying be-
low the device
Tap drips when
heating up
Bubbling noises
in the tank
The leakage current cir-
cuit breaker is triggered
The device does
not operate at all
28
GB
F
Explanation
No voltage
Device has reached the
set temperature
Thermostat set incorrectly
Water pressure too low
Stop valve not fully open
No water
The device is leaking
Water pipes are not securely
connected to the device
Is normal due to the expan-
sion of the heated water
T oo much calcification
T oo many devices on
the safety group
If the device no longer operates, check whether the fuse
or the leakage current circuit-breaker has tripped. The hot
water reservoir is equipped with a maximum temperature
switch to ensure your safety. The device will automatically
switch off if excessive heating takes place. When this hap-
pens, switch off the appliance for a few minutes by remov-
ing the plug from the power supply socket and allow the
appliance to cool. The appliance can be reconnected to the
mains power supply again after approximately 20 minutes.
TR
PL
Solution
Check fuse and socket
No need to do anything
Change the setting of
the thermostat
Check whether other
cold water taps have
the same problem
Open the stop valve
The device should be
turned off as soon as pos-
sible! See also „The de-
vice does not work."
Notify the place of purchase
Check the water connections
No need to do anything
The device must be de-
scaled by an expert
Remove some devices from
the group or look for an
empty group