Problem Solving; Error Code Display; Technical Specification - Enodis MENUKEY2 Notice D'utilisation

Merrychef
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

PRObLeM SOLVING

error code display

The oven will identify some of the most common problems by flashing an error message
code in the time display window.
error code display
Please remember - No servicing or repairs should be carried out other than by an approved Service engineer
Technical Specifications
Microcook HD1025 & HDV1025
Microcook HD1425 & HDV1425
Microcook HD1725 & HDV1725
Microcook HD1925 & HD1925
Microcook HD2025
Manufacturers recommended
clearances
Power Supply: See rating plate at rear of oven
This equipment complies with the following EEC directives:
EMC 89/336 EEC
LVD 73/23 EEC
Merrychef reserves the right to alter specifications without prior notice.
Fault
Door not fully shut.
Possible electrical fault
Oven has overheated
No time has been set.
Invalid time has been set. e.g. 61secs
The required cooking time for multiple
items exceeds 30minutes
Display shows 0:00 but the cavity light
and cooling fans do not operate
Control panel lights do not operate with
oven connected to electrical supply.
Height
Width
( mm )
( mm )
489
500
489
500
489
650
50
50*
each side
15
Recommended action
Close door fully.
Call Merrychef Service Dept.
Clean air filter and vents
Leave oven switched on but not cooking
for 4-5 minutes.
Set a time
Set time in correct format 1:01
Remove one item and try again
Oven has gone into 'stand-by' mode, press
any pad to restart.
1. Check oven is connected to electrical
supply
2. Check fuse is correct value and in good
order.
3. Call Merrychef Service Dept.
Microwave
Depth
Wt.
Power output
( mm )
( kgs)
( watts )
425
1025
40
42.5
1425
500
42.5
1725
42.5
1925
500
42.5
2025
50
For 2 ovens side by side clearance is 100mm
*
Pt No. 32Z3046GB Issue 5