Videx 6300 Serie Manuel page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6300 Series
Art. 6388
3.5" colour display videophone
SLAVE MODE - SW2.4
This set up concerns the answering mode of the video monitor when there is more than one unit (max 4) in the same
apartment. OFF (default) = during a call, only the video monitor with extension 1 (master) will show the video. ON = the
video monitor will be switched on independently of the extension address: in this case the video monitor must be sup-
plied locally using a power supply Art. 2321 or Art. AMR-12, see notes on 12M and VA on "Connection Terminals Signals"
table (the local power supply is required for each black & white slave videophone or starting from the third slave videophone when
they are all colour videophones).
If you set for one slave videophone, you must set ON the same switch also for the relevant master videophone.
NOTE: WHEN USING CST2310 CONCIERGE
To enable calling to the concierge and receiving
calls from the concierge; on the master device (SW3
Dip 2&3 OFF), set dip switch 1 of SW2 to OFF and
also dip switch 4 of SW3 to ON. Intercommunication
is between devices in the same apartment.
CONNECTION TERMINALS SIGNALS
BUS1 Bus input
BUS2 Bus input
GND
Ground
+12Vdc power supply input (Art. 323/12 or Art. AMR2-
12) for version with Memory Board option or auxiliary
12M
power supply input (to be used when two or more slave
monitors are ringing together with the switch 4 of SW2
is set to ON)
GND
Ground
+30Vdc power supply input (Art.  2321) to be used
VA
when two or more slave monitors are ringing togeth-
er with the switch 4 of SW2 set to ON
Dry contact. Internally linked to NO
C
when the
button is pressed.
Dry contact. Internally linked to C
NO
when the
button is pressed.
–DOL Auxiliary LED power supply input (ground)
+DOL Auxiliary LED power supply input (+12Vdc)
Ground output for use in combination with AL & LB
GND A
active low inputs
LB
Local bell input (active low)
AL
Alarm input (not implemented yet)
Art. 6388 - Installation instructions
TECHNICAL SPECIFICATIONS
Housing and mounting: 6300 Series - Surface
SW3
Push buttons:
ON
Programming:
1
2
3
4
Controls:
Power consumption:
Working voltage:
MEMORY BOARD
This device is also available in the version with
memory board (Art. 6388/VM).
If you have that version, please refer to the
"6200, 6300, 6400 and 6700 Series Memory
Board" user manual for installation and use.
The manual is available for download:
Max 35Vdc,
click/tap or scan the QR code.
50mA
- 4 -
4
Through buttons and dip-switches
Speech volume
Call tone volume
Brightness
Colour intensity
Contrast
Stand-by:
1/3mA
Operating
150mA
Peak:
200mA
Supplied by the BUS line
66251150 - V4.7 - 15/03/22
ON
1 2 3
4
SW2.4