Lincar Lola 540 VT Instructions page 54

Appareil à combustible solide avec chaudière: pellets de bois
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

APPPLIANCE REGULATION
(to be completely carried out before effecting the 1st Lighting)
REGULATION of Heating water Temperature.
The appliance is provided with a thermostat put on the boiler for the control of the water
temperature sent to the plant, this thermostat reduces progressively the power of the appliance
(modulation) whenever the temperature of the water inside the boiler has reached the selected
temperature.
IN ORDER TO SELECT Water temperature (boiler)
- Push on button 1
-Regulate the temperature of plant utilizing the buttons P1 and P2
-Terminate the regulation of the temperature of the water pressing
shortly on button P4, the modification will be memorized and the
display returns to the previous indication
REGULATION of the Power of the appliance.
The appliance has the possibility to be regulated within a range of 5 power levels (1-min, 5-
max), during the first working hours we suggest to put the power regulation on level 3.
The appliance will use the selected power value as maximum value for the function of heating
of the plant, in this way it is possible to restrict the max. power of the appliance.
In any case if the selected power permits to the boiler temperature to reach the selected value,
the appliance will automatically reduce the power (modulation) in order to reduce the
consumption of the fuel.
- Push on P5
- Regulate the power of the appliance utilizing the buttons P5
o P6
- Terminate the regulation of the temperature of the water pressing
shortly on button P4, the modification will be memorized and the
display returns to the previous indication
REGULATION of the Room Temperature
The setting of the room temperature means to put a limit to the heating process of the
appliance, whenever the room temperature exceeds the selected value (i.e. 20°C) the
appliance reduces automatically the power commuting on minimum (power 1)
- Push on P2
- Regulate the temperature the buttons P1 and P2
- Terminate the regulation of the temperature of the water
pressing shortly on button P4, the modification will be
memorized and the display returns to the previous indication
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
GB
GB
FR
FR
54/140
ES mod. 540 VT – 540N VT
ES
ES

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Malika 540n vt

Table des Matières