Emglo E810-4V Guide D'utilisation page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CoDE
poSSIBLE CAuSE
17
Carbon build-up in pump.
Detergent type oil being used in pump
18
19
Motor overload protection switch has tripped
Extension cord is wrong length or gauge
20
Loose electrical connections
21
22
Possible defective motor or starting capacitor
23
Paint spray on internal motor parts
Fuse blown, circuit breaker tripped
24
Tank pressure exceeds pressure switch cut-in pressure
25
26
Pressure release valve on pressure switch has not
unloaded head pressure
poSSIBLE SoLuTIon
Contact an authorized service center.
Drain oil and refill pump with ISO 100/SAE40, non-deter-
gent, premium air compressor oil.
See Motor overload under Features.
Check for proper gauge wire and cord length. See
Extension Cords under Installation.
Contact an authorized service center.
Contact an authorized service center.
Contact an authorized service center. Do not operate the
compressor in the paint spray area. See flammable vapor
warning.
1. Check fuse box for blown fuse and replace as
necessary. Reset circuit breaker. Do not use a fuse or
circuit breaker with higher rating than that specified
for your particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper
extension cord.
4. Disconnect the other electrical appliances from circuit
or operate the compressor on its own branch circuit.
Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact an authorized service center.
23

Publicité

Table des Matières