Problem
Hot air in the "
cold"
programme.
The Start / Stop
light is flashing
Low air pressure in
the ironing dummy.
Excessive air pressure
the ironing dummy.
No air pressure in the
arms.
Ironing process too long. The 10 A version was used.
The ends of the
adjustment cords used to the gap on the button band.
regulate size have
become hooked up on
the appliance.
The fuse triggers when
the appliance is
connected.
You hear a noise on
raising or lowering the
appliance.
Before calling the Technical Service
Possible cause
This is not a fault! Residual heat.
The start/stop button has been pressed It stops after 30 seconds or
during an ironing cycle: pause function when start/stop is pressed.
The ironing programme blows
cold air for the last minute.
The ironing dummy has not been
fitted properly.
The air filter is dirty.
Faulty ironing dummy.
The airbag is not fitted properly.
The ironing dummy arms are twisted.
The airbag arms are not inside the
ironing dummy arms.
The end of the cord has splipped into
The wrong connection current has
been selected.
This is because the internal tube is
sliding
Solution
The hot air disappears after a
short period of time.
Indicates that the cycle is
finishing and the appliance
has begun to blow cold air.
Fit the ironing dummy correctly.
Clean the air filter.
Replace the ironing dummy.
Check the airbag adjustment in
cords and adjust them correctly.
Set the arms in the right
position.
Insert the airbag arms in the
ironing dummy arms. Fig. 25.
Switch over to the 16 A version
if possible.
Press the button band adjuster
in and pull on the cord.
Select the right connection
current. See "Changing the
connection current".
This is not a fault and does
not affect correct operation
of the appliance.