AVIRE Memcom+ Guide D'installation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Full Programming Options
Menu Sections
System Config+
Auto Location
x
ü
Avoid Silence
x
ü
Quick Dial
x
ü
Quick VAD.
ü
x
Dialtone req
x
ü
Lineflt. Alert
ü
x
Hotline
x
ü
Hardware (HW) Monitoring
Hardware monitoring sets which system elements are checked when
the unit completes its self-check and places a test call. Default
settings are shown below:
Power Supply
ü
Battery
ü
Phone Line
ü
GSM low sig.
û
GSM no sig.
û
Spkr/mic.
ü
GSM Status
û
When an operator answers an alarm call, the Memcom
automatically play the location message.
NOTE: when programming in the alarm numbers
'UNGUIDED' protocol must be selected (see section on Alarm
Numbers for more detail).
During an alarm call the Memcom
will not mute its speaker,
+
unless the operator presses the '2' key on their handset.
Reduces the dial tone detection test from 7 seconds to 3
seconds – prevents issues with exchanges timing out after 4
seconds.
Allows the Memcom
+
to detect speech before the first ring
pulse has been sent down the line.
Requires the Memcom
to detect a dial tone before it attempts
+
to dial out.
If the phone line to the Memcom
+
is cut, the unit will play an
audible warning message. The message will repeat every 3
minutes unit the phone line is restored.
Tells the Memcom it is connected to a hotline, allowing any
other of the call protocols to then be selected for use on that
line.
+
will
9 9