Restart; Offset Calibration - OJ Electronics ETO2 Instructions

Contrôleur électronique pour la fonte totalement automatique et économique de la glace et la neige sur les surfaces extérieures et dans les gouttières.
Masquer les pouces Voir aussi pour ETO2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 85
English / User Manual
MAX WATER
55.0C
SENSOR HEAT
AUTO
MOIST CTRL
ON
SENSITIVITY
NORM
LANGUAGE
ENGLISH
FACTORY RESET
REINSTALL
REINSTALL
PASSWORD
XXXX
EXIT

RESTART

After changing the settings, or whenever a new process start is required, the ETO2 can be restarted in
this menu.
RESTART

OFFSET CALIBRATION

If it is necessary to calibrate the temperature measured by the ETOG sensor, please follow the steps
below:
56
The maximum supply water temperature can be set here. Set the required
maximum temperature and press OK.
This menu option is only available when hydronic heating is used.
In auto mode, sensor heating is switched off during periods when snow
melting is active. Under special conditions or during extremely cold weather,
the sensor can be heated continuously. Select ON and press OK.
Moisture control can be switched off here. If so, snow and ice melting will
only be controlled by the set temperature, see SET TEMP. Select OFF to
switch off moisture control and press OK.
Note that energy consumption/costs will rise if moisture control is
switched off.
Sensor sensitivity can be adjusted in 5 steps: MIN: e.g. for salted roads -
LOW: e.g. for dirty snow - NORM: e.g. for mixed snow conditions - HIGH:
e.g. for white snow - MAX: e.g. for very pure snow or hoar frost. To change
sensitivity, press OK, turn the encoder button to the desired setting and
confirm with OK.
Language information.
All ETO2 factory settings can be restored here. Selecting this option deletes
all customised settings.
In the event of setup failure in the STARTUP menu, or whenever new
PASSWORD and turn the encoder button to the factory code (1202). The
controller will then return to the STARTUP menu, see STARTUP.
Select this option and press OK to return to the main menu.
Restarts operation while retaining all your current settings. The ETO2 goes to the
initial status display.
© 2020 OJ Electronics A/S
hardware is connected, the primary setup must be
changed in the STARTUP menu. Select
Type ETO2