Installation

WARNING!
Electric shock!
Upon opening the housing, live parts are exposed!
Î Always disconnect the device from power supply
before opening the housing!
2.1

Mounting

Note
Strong electromagnetic fields can impair the function of the device.
Î Make sure the device as well as the system are not exposed to strong
electromagnetic fields.
The device must only be located in dry interior rooms.
The device must additionally be supplied from a double pole switch with contact
gap of at least 3 mm.
Please pay attention to separate routing of sensor cables and mains cables.
Î Unscrew the crosshead screw from the cover and remove the cover.
Î Mark the upper fastening point on the wall. Drill and fasten the enclosed wall
plug and screw leaving the head protruding.
Î Hang the housing from the upper fastening point and mark the lower fastening
points (centres 180 mm).
Î Drill and insert the lower wall plug.
Î Fasten the housing to the wall with the lower fastening screw and tighten.
12
crosshead
screw
cable conduits with
strain relief
180
180
208
180
cover
fuse / spare fuse
upper fastening
180
180
208
lower fastening