OEG KSW-E Serie Mode D'emploi page 39

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Para-
Function
meter
SENSOR FOR
F2.7
THERMOSTATIC
OPERATION
THERMOSTAT
F2.8
HYSTERESIS
F2.9
AUXILIARY HEAT
SOURCE -
DELAYED ACTIVA-
TION
F2.10 AUXILIARY HEAT
SOURCE -
STANDBY AT MIN.
TEMPERATURE
F2.11 DIFFERENTIAL
THERMOSTAT
F2.12 HEAT SOURCE
SENSOR FOR DIFF.
THERMOSTAT
F2.13 HEAT SINK SEN-
SOR FOR DIFF.
THERMOSTAT
F2.14 SWITCH- ON DIFFE-
RENCE FOR DIFFE-
RENTIAL THERMO-
STAT
F2.15 SWITCH- OFF DIF-
FERENCE FOR
DIFFERENTIAL
THERMOSTAT
F2.16 CIRCULATION ON
OUTPUT
Parameter description
Selection of sensor for thermostatic operation.
Hysteresis for thermostatic operation.
Selection if auxiliary heat source should activate immediately or with
delay if the collectors have trend and tendency to warm the water to
requested temperature. Delay time is considered as a time in which
the collectors should warm the water to requested temperature.
Auxiliary heat source will activate immediately if collectors don't have
trend and tendency to warm the water to requested temperature in
setted delayed activation time.
Selection if auxiliary heat source should permanently heat the water
to min. temperature.
Selection if programmed output should operate as a differential
thermostat.
Selection of heat source sensor (higher temperature) for differential
thermostat.
Selection of heat sink sensor (lower temperature) for differential
thermostat.
Switch -on difference setting for differential thermostat.
Switch -off difference setting for differential thermostat.
Selection if output should be used for hot water circulation and the
way it should operate.
1- circulation with pump running and standby time
2- circulation is activated with flow switch on terminal T3 and is
running for setted running time
3- circulation is activated with flow switch on terminal T4 and is
running for setted running time
4- circulation is activated with flow switch on terminal T5 and is
running for setted running time
5- circulation is activated with flow switch on terminal T6 and is
running for setted running time
41
Default
Setting range
value
1- T1 2- T2
4
3- T3 4- T4
5- T5 6- T6
1 ÷ 30 °C
4
0- NO DELAY
0
1 ÷ 1440 min-
DELAY
0- NO
0
1- YES, BY TIME
PR.
2- ALWAYS
0- NO
0
1- YES
2- YES, INVERTED
1- T1 2- T2
3
3- T3 4- T4
5- T5 6- T6
1- T1 2- T2
4
3- T3 4- T4
5- T5 6- T6
4 ÷ 30 °C
8
3
1 ÷ 20 °C
0- NO
0
1- YES, RUN/
STANDBY TIME
2- YES, T3
3- YES, T4
4- YES, T5
5- YES, T6
Service settings manual