Filter Replacement - Aerus ORIGINS RO400 Manuel D'utilisation

Systéme de filtration d'eau par osmose inverse
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FILTER REPLACEMENT

1. Turn off cold water shut-off valve to the RO Filter System.
2. Turn cartridge clockwise until unit releases. Gently pull down to remove from head. Discard used cartridge.
Notice: Place a bucket or pan under system to catch any water drips.
3. Hold new cartridge with label slightly facing left. The two nozzles on top of cartridge should be toward the
back of the Filter System, and the two extended flanges should be out to each side.
Notice: Part No. 49452 (Sediment) should be in stage 1, Part No. 49453 (Pre-Carbon) should
be in stage 2, Part No. 49445 (RO Membrane) should be in stage 3 and Part No.
49446 (Post-Carbon) should be in stage 4.
4. Lift cartridge straight up into the manifold until the two nozzles seat into the manifold ports, and the two
extended flanges are flush with the manifold.
5. Turn cartridge counter-clockwise until it stops.
6. Turn on cold water shut-off valve and RO faucet. Check for leaks.
7. Pressure test and Purge per Step Eight on page 10.
A
Bottom of
Manifold
A
Bottom of
Manifold
OPTIONAL LEAK PROTECTOR TABLET REPLACEMENT – PART NUMBER LPSOV-PAD
1. Turn off the water supply at the cold water valve.
2. Using a Phillips screwdriver, loosen and remove screw from the top of the valve.
3. Twist the upper white assembly counter clockwise, lift up and remove old tablet.
4. Make sure the valve and the surrounding area are dry before replacing the tablet.
5. Insert the new applicator tablet into the clear plastic housing.
6. Replace the upper white cap onto the clear plastic base by twisting it clockwise until seated.
7. Replace Phillips screw and tighten (Do not overtighten as this may damage the valve unit).
8. Turn on the water supply to the filtration unit and check for leaks.
CAUTION: Keep Leak Protector Replacement Cartridges (pads) out of the reach of children and pets.
DRAIN FLOW RESTRICTOR
The restrictor is vital for proper operation of the RO membrane cartridge as it keeps water flowing through the membrane at the proper rate
ensuring the water produced is the best quality. It is recommended the restrictor assembly be periodically inspected to be sure it is clean
and unrestricted. If service is required on the drain flow assembly, disassemble and reassemble as outlined in Step Six on page 9.
Top of Cartridges