Your Direct Vent Wall Furnace is shipped complete in one carton. This carton contains the furnace, vent cap, vent tube, air
inlet tube, template with rough-in dimensions, installation and operating instructions, and the thermostat with thermostat wire.
NOTE: There will be two cartons if an optional vent kit or blower is purchased.

MODEL NUMBERS

Gas Type
Height
Width
Depth
Input (BTU / HR)
Gas Inlet
Vent Size / Wall Opening
Minimum - Maximum Wall Thickness
Approximate Shipping Weight
Optional Blower Model
THIS IS A GAS-FIRED, DIRECT VENT WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT
SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION
AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, SERVICING,
OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS CONSULT
LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE TECHNICIAN, THE GAS SUPPLIER OR THE
MANUFACTURER.
1. Improper installation, adjustment, alteration, service, or
maintenance can cause property damage, bodily injury
or death.
2. Use in anything other than a residential application may
result in unsatisfactory performance and may void the
warranty.
3. This appliance must be installed in accordance with local
codes, if any; if not, follow the National Fuel Gas Code
ANSI Z223.1/NFPA 54 or the National Gas and Propane
Installation Code CSA-B149.1.
4. Do not install this wall furnace in a recreational vehicle or
trailer.
5. Do not operate wall furnace unless it is connected to the
factory supplied vent system with vent cap in place.
6. Check the rating label attached to the wall furnace to be
sure it is equipped for the type gas you intend to use.
7. Never use a match, candle, flame or other source of
ignition to check for gas leaks. Use only soapy water or
liquid detergent.
SPECIFICATIONS & DIMENSIONS
CDV155C
CDV156C
Natural
Propane
29-3/4"
18"
9-3/4"
15,000
1/2"
9"
5" - 24"
65 lbs
DVB3

INTRODUCTION

SAFETY

8. Have your wall furnace and vent system inspected at
least annually by a qualified service technician.
9. Before cleaning or servicing, turn off the gas and allow
furnace to cool.
10. Do not operate wall furnace without outer casing in place.
11. Due to high temperatures, the wall furnace should be
located out of traffic and away from furniture and drapes.
12. Children and adults should be alerted to the hazard of
high surface temperature and should be kept away to
avoid burns or clothing ignition.
13. Young children should be carefully supervised when they
are in the same room with the wall furnace.
14. Do not place clothing or other flammable material on/
near the furnace.
15. Installation and repair should be done by a qualified
service technician. The wall furnace should be inspected
before use and at least annually by a professional service
technician. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, etc.
Page 3
CDV255C
CDV256C
CDV355C
Natural
Propane
Natural
31-3/4"
34-1/2"
9-3/4"
35,000
1/2"
9"
5" - 24"
99 lbs
DVB3
Back to Index
CDV356C
Propane
31-3/4"
34-1/2"
9-3/4"
50,000
1/2"
9"
5" - 15"
99 lbs
DVB3
1017757-A