This kit must be installed by a qualified installer or service technician only.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper operation after servicing.
STEP 1.
Remove outer casing.
STEP 2.
Remove floor shield from bottom of heater and disconnect
piezo wire.
STEP 3.
Remove and discard cover shield. Save screws.
STEP 4.
Attach blower to bottom of floor shield using screws saved
in Step 3. Note: Blower motor should be on the opposite
end from piezo.
STEP 5.
For models CDV25/33-C, secure P/N 43625 blower shield
to bottom of heat shield using two (2) #8x1/2" screws
provided. See figures 14-A and 14-B.
STEP 6.
Connect piezo wire and attach floor shield to heater.
Slide the white cable clamp (provided) over both motor
lead wires and the power cord. Secure to left side of
heater with the front screw used to secure the floor shield.
STEP 7.
Attach the junction box to left side of wrapper using four
#8x1/2" screws provided.
STEP 8.
Plug power cord into a 115 volt grounded outlet.
STEP 9.
Replace outer casing and follow lighting instructions to
place heater in operation.
WARNING: The unit must be electrically grounded
according to the national electrical code ANSI/NFPA no.
70-1987. This appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard
and must be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
Note: This blower assembly is equipped with a temperature activated
fan switch that will automatically cycle the blower on when the heat
exchanger has reached a predetermined temperature. Once the
burner shuts off, this switch will cycle the blower off after the heat
exchanger cools to the fan switch differential setting. This blower will
not operate unless the main burner is in use.
1017757-A
DVB-3 BLOWER KIT INSTALLATION - ( OPTIONAL )
Compatable with CDV15-C / CDV25-C / CDV33-C Series.
FIG. 14-A
Floor
Shield
Cover Shield
(Remove
& Discard)
Blower
FIG. 14-B
Floor
Shield
Blower
Shield
P/N 43625
Cover Shield
(Remove
& Discard)
Page 16
Back to Index
CDV25-C / CDV33-C
Blower
CDV15-C
3-5/8"
1-3/4"

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cdv156cCdv255cCdv256cCdv355cCdv356c

Table des Matières