BEHA Unitest 9004 Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Automatic Power-Off
Temperature Range:
– Operation
– Storage
Height abover MSL:
Security:
Rated voltage towards ground:
Overvoltage class:
Contamination degree:
Power Consumption max.:
Power Supply:
Dimensions*:
Weight*:
* Dimensions and weight incl. Protective Rubber Holster
Model 9004: Measurement Ranges:
DC Voltage
Meas. Range
200 mV
2000 mV
20 V
200 V
600 V
AC Voltage (50 ... 200 Hz)
Meas. Range
200 mV
2000 mV
20 V
200 V
600 V
DC Current
Meas. Range
20 mA
200 mA
15 A
Input current 10 ... 15 A for a maximum of 15 seconds
AC Current (50 ... 200 Hz)
Meas. Range
20 mA
200 mA
15 A
Input current 10 ... 15 A for a maximum of 15 seconds
Model 9004
10 mA / 0.1 W
9 V Battery IEC 6LR61 2x1.5V Batteries IEC LR6
165 x 78 x 50 mm
340 g approx.
Accuracy
Resolution
0.1 mV
1.0 mV
% (0.8 % rdg
10 mV
+ 2 digits)
100 mV
1 V
Accuracy
Resolution
0.1 mV
1.0 mV
% (1.5 % rdg
10 mV
+ 3 digits)
100 mV
1 V
Accuracy
Resolution
10 µA
% (1.2 % rdg + 2 Digits)
100 µA
% (1.2 % rdg + 2 Digits)
10 mA
% (2.0 % rdg + 3 Digits)
Accuracy
Resolution
10 µA
% (1.2 % rdg + 3 digits)
100 µA
% (1.2 % rdg + 3 digits)
10 mA
% (2.0 % rdg + 3 digits)
Model 9005
after 10 minutes approx.
23° C % 5° C
0 ... 40° C
–10° C ... +60° C
up to 2000 m
EN 61010/IEC 61010
max. 600 V
II up to 600 V
III up to 300 V
2
max 1.9 mA / 6 mW
165 x 78 x 50 mm
380 g approx.
Input-
Resistance
10 MV
Input-
Resistance
10 MV
Load-
Voltage
200 mV
Load-
Voltage
200 mV
Overload prot.
600 V
AC/DC
Overload prot.
600 V
AC/DC
Overload prot.
200 mA/250 V
12,5 A/250 V
Overload prot.
200 mA/250 V
12,5 A/250 V
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Unitest 9005

Table des Matières