  • Page 1 Original instructions Arden 4200 ..16 ..20 ..25 ..30 ..35 ..41 ..46 ..51 ..57 ..62 ..68 ..73...
  • Page 2 Arden 4200 The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Page 3 Arden 4200 1 m: 4 x M8 1,5 m: 4 x M8 2 m: 6 x M8 2,5 m: 6-8 x M8 ø29 ø29 ø29 ø29 [mm] [mm] ARFEC4210 1067 1020 ARFEC4215 1577 1520 ARFEC4220 2067 2020 ARFEC4225 2579 2520...
  • Page 4 Arden 4200 Mounting on threaded bars outside the unit Top view ARFEC4210 ø29 ø29 1400 ARFEC4215 ARFEC4220 ARFEC4225 1198 1198...
  • Page 5 Arden 4200 Mounting on threaded bars outside the unit Fig. 1a: Mounting brackets on delivery. ARFEC4220 ARFEC4225 Fig. 1b. Mounting on threaded bars outside the unit.
  • Page 6 Arden 4200 Mounting on threaded bars inside the unit Top view ARFEC4210 ø29 ø29 ARFEC4215 ARFEC4220 ARFEC4225...
  • Page 7 Arden 4200 Mounting on threaded bars inside the unit 1 m: 4 x M8 1,5 m: 4 x M8 2 m: 6 x M8 2,5 m: 6-8 x M8 Fig. 2. Mounting on threaded bars inside the unit.
  • Page 8: Electrical Installation

    Arden 4200 Service hatch 90° Fig. 3: Snap fixings PC board FC Fig. 4: PC board FC is integrated within the air curtain at delivery Electrical installation Water connections Fig. 5: Pierce the gland with a screwdriver before Fig. 6: Hoses are mounted via cable glands at entering the cable.
  • Page 9: Accessories

    Arden 4200 Accessories PA34TR PA34CB PA34VD FH1020 AR42XTT Item Type Consists Dimensions number PA34TR15* 18056 ARFEC4210/4215 4 pcs L: 1 m PA34TR20* 18057 ARFEC4220 6 pcs L: 1 m PA34TR30* 18058 ARFEC4225 8 pcs 18059 PA34CB15* ARFEC4210/4215 4 pcs 18060...
  • Page 10 Arden 4200 Control systems The air curtain must be supplemented with a control system. FCDA - FC Direct FCSA - FC Smart FCCF FCDC FCBC10 FCLAP FCCF FCDC FCBC05 FCPA - FC Pro FCBA - FC Building FCCF FCDC FCBC10...
  • Page 11 Arden 4200 ARFEC4200 A 3510: 2 Motors 4210/5010: 3 Motors 3515: 3 Motors 4215/5015: 4 Motors 3520: 4 Motors 4220/5020: 6 Motors 3525: 5 Motors 4225/5025: 7 Motors +12V +12V FCBASE REA Trafo PAFEC/ARFEC 3500 A PAFEC/ARFEC 4200 A PAFEC/ARFEC 5000 A 230V~ Wiring diagrams for control system in the FC manual.
  • Page 12 Arden 4200 ARFEC4210/4215 E 3510: 2 Motors 4210/5010: 3 Motors 3515: 3 Motors 4215/5015: 4 Motors Inlet sensor Outlet sensor +12V +12V FCBASEPCB REA Trafo PAFEC/ARFEC 3510E/3515E PAFEC/ARFEC 4210E/4215E PAFEC/ARFEC 5010E/5015E 317533 230V~ 400V 3~ Wiring diagrams for control system in the FC manual.
  • Page 13 Arden 4200 ARFEC4220/4225 E A1 A2 B1B2 D1 D2 Termination 230V IN BUS 1 BUS 2 Wiring diagrams for control system in the FC manual.
  • Page 14 Arden 4200 ARFEC4200 W 4210/5010: 3 Motors 3510: 2 Motors 3515: 3 Motors 4215/5015: 4 Motors 3520: 4 Motors 4220/5020: 6 Motors 3525: 5 Motors 4225/5025: 7 Motors Inlet sensor Outlet sensor +12V +12V BaseW Trafo PAFEC/ARFEC 3500 W PAFEC/ARFEC 4200 W...
  • Page 15: Technical Specifications

    ) ∆t = temperature rise of passing air at maximum heat output and low/high airflow (2/10V). ) Applicable at water temperature 60/40 °C, air temperature, in +18 °C. ) Applicable at water temperature 40/30 °C, air temperature, in +18 °C. ) See www.frico.net for additional calculations.
  • Page 16: Généralités

    Application l’appareil pour le transport. Les desserrer, les retourner et les visser sur l’appareil comme Arden 4200 est un rideau d'air pour montage indiqué sur la fig. 1a. encastré. Hauteur d’installation préconisée 4,2 m. Le rideau d'air est disponible sans 2.
  • Page 17 L'alimentation électrique pour le chauffage Noter que l'appareil doit être précédé d'une (400 V3~) est acheminée via le bloc moteur, vanne de régulation ; voir le kit de vannes Frico. sécurisée à l'aide de colliers de serrage Pour accéder aux connexions, la trappe préinstallés, et connectée au bornier dans...
  • Page 18: Entretien

    Arden 4200 l'orientation et de la vitesse du débit d'air peut de 2 m et 2,5 m sont équipés de boutons s'imposer en fonction de la charge. rouges, un sur l'extérieur de chaque boîtier de raccordement. Filtre (W) 4. Appuyer sur le bouton rouge jusqu’à...
  • Page 19: Remplacement De La Carte Électronique

    Arden 4200 Remplacement de la carte électronique disjoncteur différentiel, de sorte à sécher 1. La carte électronique se trouve dans le l'élément de chauffe. Le séchage peut prendre bornier. Fig. 4 de quelques heures à quelques jours. À titre 2. Repérer et débrancher les câbles de la carte préventif, il est conseillé...
  • Page 20: Caractéristiques Techniques

    ) ∆t = augmentation de température sous une puissance maximale et un débit d'air faible/élevé (2 V/10 V). ) Valable pour une temp. d’eau de 60/40 °C, temp. d’air d’entrée +18 °C. ) Valable pour une temp. d’eau de 40/30 °C, temp. d’air d’entrée 18 °C. ) Consultez www.frico.fr pour des calculs supplémentaires.
  • Page 21 Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net...