3. Reinstall the wire compartment cover using the two screws
removed in Step 2 of SECTION 1 Preparing the Unit . Make
sure all wires are tucked inside of the compartment and
are not being pinched or showing through.
SECTION 5

Completing the Installation

1. Remove grill from carton and attach springs from grill to posts
on either side of housing (Figure 6).
Grill
Springs
Figure 6
5. Install a 250 watt maximum, R-40 Type A heat lamp (not
included) into the socket and center the grill around the
lamp.
NOTE: Model AK927 uses 2 - 250 watt maximum R-40, Type A
heat lamps.
6. Restore power and test your installation.
Trouble
1. Lamps do not operate when switch is on.
210575912 Rev. A 1-06
Posts

Troubleshooting Guide

Probable Cause
1a. A fuse may be blown or a circuit tripped.
1b. Heat Bulb(s) is burned out
1c. Wiring is not connected properly.
www.airkinglimited.com
SECTION 6
Use and Care
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE SERVICING THE UNIT.
CAUTION:
ALLOW LAMP(S) TO COOL BEFORE CLEANING
THE UNIT OR REPLACING THE LAMPS.
1. Cleaning the Grill: Remove heat lamp(s) and detach grill springs
from posts to release grill from housing. Use a mild detergent,
such as dishwashing liquid, and dry with a soft cloth. NEVER
USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry grill before reinstalling. Refer to instructions in
Section 5 Completing the Installation , to reinstall grill.
CAUTION:
ALLOW LAMP(S) TO COOL BEFORE REPLACING.
2. Changing the Heat Lamps: Disconnect power to the unit.
Unscrew heat lamp(s) from lamp holder and replace with 250
watt maximum, R-40, type A heat lamp.
Suggested Remedy
1a. Replace fuse or reset circuit breaker.
1b. Turn off power to unit. Replace bulb(s). Restore power to unit.
1c. Turn off power to unit. Check that all wires are connected.
3 of 8