AirKing AK912 Mode D'emploi page 2

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Unit
1. Unpack unit from the carton and confirm that all pieces are
present. In addition to the unit you should have:
1 - Grill
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Remove the wire compartment cover by loosening the two
screws holding the cover in place (Figure 1).
Figure 1
WARNING:
DO NOT INSTALL OVER A TUB OR MOUNT IN
A SHOWER STALL ENCLOSURE.
3. Choose the location for your unit. This unit will require at
least 6" of clearance in the ceiling, and will mount through
drywall up to 3/4" thick. The unit
mounts between 16" on center joists
using the provided mounting rails.
4. Select the most convenient electrical
knockout and remove using a straight-
blade screw driver (Figure 2).
SECTION 2
New Construction
1. Install the rails on the housing and position the housing next
to the joist. Line up housing so it will be flush with the finished
ceiling. Secure the ends of the rails with screws or nails
(not included) to the joists and slide housing into final position
(Figure 3).
Housing
Joist
Figure 3
210575912 Rev. A 1-06
Screws
Wire
Compartment
Cover
Figure 2
Mounting Rails
www.airkinglimited.com
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline
onto the ceiling material (Figure 4). Set housing aside and
cut opening, being careful not to cut or damage any electrical
or other hidden utilities. Install the rails on the housing and
position the housing in the previously cut hole so that it is
flush with the finished ceiling. Secure the ends of the rails
to the joists with screws or nails (not provided) to ensure
proper installation (Figure 3).
Figure 4
SECTION 4
Wiring
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION:
ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE
THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green
or bare copper), and one hot (black). Secure the electrical
wires to the housing with an approved electrical connector.
Make sure you leave enough wiring in the box to make the
connection to the unit's receptacle.
2. From where you have access to inside the unit's junction
box, connect the White wire from the house to the White
wire from the unit. Connect the Hot (Black) wire from the
house to the Black wire from the unit. Connect the ground
wire from the house to the Green wire from the unit (Figure
5). Use approved methods for all connections.
NOTE: On model AK922 connect the Hot (Black) wire from the
house to both the black and red wires from the unit.
Hot (Black)
Figure 5
Ground
Hot (Blue)
(Model AK922)
White
2 of 8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ak922

Table des Matières