Accessories; Troubleshooting - Arctic Cove MAC3810K Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To order these accessories, call 1-877-297-8911
 Brass Nozzle ........................................................................................................................................ Model No. MAC080
 Misting Tube .............................................................................................................Model No. MAC3824T or MAC3820T
 3/8 in. Booster Pump ........................................................................................................................... Model No. MBP160
 Inline Misting Filter ............................................................................................................................. Model No. MACF009
 Nozzle Cleaner .................................................................................................................................. Model No. MACC008
 Drain Valve ........................................................................................................................................... Model No. MAC100
WARNING:
Current attachments and accessories available for use with this product are listed above. Do not use any attachments
or accessories not recommended by the manufacturer of this product. The use of attachments or accessories not
recommended can result in serious personal injury.
PROBLEM
Leak at nozzle or threaded hole
Misting kit will not spray
Loss of pressure
Water stuck in misting tube after use
Drain valve leaks during use.

ACCESSORIES

TROUBLESHOOTING

POSSIBLE CAUSE
Nozzles were installed improperly.
Nozzles clogged or dirty.
Hose faucet is closed.
T-filter is clogged.
Nozzles clogged or dirty.
T-filter is clogged
Debris in misting kit.
Leak in misting tube.
Misting tube connected to T-filter.
Defective drain valve.
Defective drain valve.
This product has a one year Limited Warranty.
For Warranty details go to www.arcticcove.com
SOLUTION
Reinstall nozzles and tighten securely.
Clean nozzles.
Turn hose faucet completely on.
Follow instructions for cleaning strainer
in Maintenance.
Clean nozzles.
Follow instructions for cleaning strainer
in Maintenance.
Follow instructions for flushing the
system in Assembly.
Replace misting tube.
Disconnect misting tube from T-filter
and allow water to drain.
Replace drain valve.
Replace drain valve.
7 — English