Safety instructions
WARNING
Risk of burns!
The radiator's surface can heat up to 110 °C
(230 °F).
Be careful when touching the radiator.
CAUTION
Risk of burns due to squirting hot water
when evacuating air!
Protect your face and hands.
Maintenance
Vent the radiator after commissioning and
following lengthy interruptions of opera-
tion.
Use a commercially available radiator key.
Cleaning
Use only mild, non-abrasive cleansing
agents.
Complaint
Contact your local dealer.
Installation and repairs
Have the installation and repairs performed
by a specialized tradesman so that your
claims under warranty are not forfeited.
Disposal
Recycle or dispose of disused radiators, in-
cluding accessories, properly. Observe local
regulations.
EN – Installation instructions
The radiator may only be installed by a special-
ized tradesman.
Safety instructions
Read these instructions thoroughly prior to
installation/commissioning.
After installation pass the instructions on to
the end used.
WARNING
Risk of injury!
Take the weight of the radiator into ac-
count (see manufacturer's data).
At 25 kg and above, work with lifting
equipment or several persons.
Operating conditions
Observe operating conditions for wa-
ter heating installations according to
DIN 18380 "VOB German Construction Con-
tract Procedures".
Observe water's condition according to VDI
[Association of German Engineers] 2035
"Prevention of damage in water heating
installations".
Observe limitations of use in damp loca-
tions according to DIN 55900 "Coatings for
radiators".
Use radiator only in closed heating systems.
Store and transport radiator only in the
protective packaging.
Observe minimum clearances between ra-
diator and circumjacent objects for air cir-
culation.
Complaint
Contact the supplier.
Disposal
Packaging and any parts that are not need-
ed should be recycled or disposed of prop-
erly. Observe local regulations.
Technical features
Operating pressure: max. 10 bar, for high-
pressure version max. 16 bar
Test pressure: 1.3 x operating pressure
Flow temperature: hot water up to 110 °C
(230 °F)
Directions for installation
Protecting radiator from damage
When installing, only remove protective
packaging at the fastening and connection
points.
Only remove protective packaging com-
pletely during final cleaning or prior to
commissioning.
Connecting blocks
Assembling radiators delivered in blocks
(see separate installation instructions).
9