Compressor (cont'd)
TROUBLE SHOOTING (cont' d )
Motor will not run (cont' d )
Fuse blown or circuit breaker tripped
Replace blown fuse or reset circuit breaker. Do not use fuse or circuit breaker with high rating
than specified for your ranch circuit.
Check for low voltage and proper extension cord size.
Disconnect other applications from circuit. Operate compressor on a dedicated circuit.
Check valve stuck open
Remove and clean or replace
If bleeder valve does not open
Replace bleeder valve.
Wrong wire gauge in extension cord
Check for proper gauge and extension cord length.
Paint spray on internal motor parts
Bring to service centre for service. Do not operate compressor in the paint spray area.
Possible defective motor
Bring to service centre for inspection and repair.