Installation And Mounting - Ecco ED5100 Instructions D'installation Et D'utilisation

Module d'angle del
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Mounting

Before installation, examine the LED heads for transit damage. Do not use damaged or broken parts.
The mounting location should allow the maximum visibility of the warning device to other road users, while allowing for sufficient wire access.
Wire functions are as follows:
Black Wire:
Negative. Connect to either the battery negative terminal or a suitable chassis point.
Red Wire:
Power. Switch to 12-24V to operate the module. Must be powered through the fuse, located as close to the battery
terminal as possible.
Purple Wire:
(DUAL COLOUR MODULES ONLY) Power. Switch to 12-24V to operate the module. Must be powered through the fuse,
located as close to the battery terminal as possible.
White Wire:
(DUAL COLOUR MODULES ONLY) Dim. Connect to 12-24V to operate the unit in dim mode.
Blue Wire:
Flash pattern set. Touch wire to Negative momentarily
(< 1 sec) to cycle through the available flash patterns (see table).
Yellow Wire:
Synchronised Flash: Connect YELLOW wires of all units together after setting all units to the same pattern.
Alternating Flash: (CAT 'X' or non-R65 arrangements only). Set all units to either Phase 1 or Phase 2 of the same flash
pattern, then connect the YELLOW wires together. Units set to Phase 1 will alternate with units set to Phase 2.
NOTE: When arranging corner Module LED's to comply with ECE R65 CAT 'HT' or 'T' all units must be set to pattern P1,
P3 or P5 and Synchronized.
Flash Patterns
The LED heads can be configured to flash the following patterns (in the order below) by momentarily making contact with the blue wire and
the negative as described in the wiring section. The LED head must be powered through the black and red wires to allow pattern selection.
Mode
Pattern
P1
ECE R65 120FPM Single Flash P1
P2
ECE R65 120FPM Single Flash P2
P3
ECE R65 Double Flash P1
P4
ECE R65 Double Flash P2
P5
ECE R65 Quad Flash 120 FPM P1
P6
ECE R65 Quad Flash 120 FPM P2
P7
Single Flash 75 (SIM) P1
P8
Single Flash 75 (SIM) P2
P9
Double Flash 75 (SIM) P1
P10
Double Flash 75 (SIM) P2
P11
Quad Flash 75 (SIM) P1
P12
Quad Flash 75 (SIM) P2
P13
OFF.
OPERATE VOLTAGE
DC 10~30V
OPERATE CURRENT
Max. 1.2A
LED COLOUR
Amber
Blue
Red
Amber & Blue
OPERATE TEMPERATURE
-40°C~+ 55°C
MAX. HUMIDITY
60%
PATTERNS
13 FLASH PATTERNS (PER LED COLOUR)
Wire function
Red wire= +VDC: Black wire= -VE: Blue=Pattern
change: Yellow=Synchronize
Tapping timing
Function
0 ~ 1 sec
NEXT PATTERN / ON
1 ~ 3 sec
PREVIOUS PATTERN
3 ~ 5 sec
FACTORY DEFAULT(P1)
OVER 5 sec
OFF
Description
R65 Single Flash.
Default Mode
R65 Single Flash.
R65 Double Flash.
R65 Double Flash.
R65 Quad Flash.
R65 Quad Flash.
SAE single Flash.
SAE Single Flash.
SAE Double Flash.
SAE Double Flash.
SAE Quad Flash.
SAE Quad Flash.
1. Default mode P1
2. The pattern will go to the previous pattern after
power off then power on.
3. "SIM" means LED lighthead at the same time "
ALT" means LED alternative flash
APPROVED MOUNTING POSITION TO COMPLY WITH ECE R65 CAT 'HT'
(ONE PAIR OF UNITS AT THE FRONT OR REAR OF VEHICLE)
VEHICLE CENTRAL AXIS
MAX DISTANCE = 10M
APPROVED MOUNTING POSITION TO COMPLY WITH ECE R65 CAT 'T'
(FOUR UNITS MOUNTED ON THE VEHICLE)
MAX DISTANCE = 10M
45º
VEHICLE CENTRAL AXIS
45º
HORIZONTAL PLANE
Center Axis of Lamp
45º
MAX DISTANCE = 10M
45º
Page 2 of 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ed5100caEd5100cbEd5100cabEd5100cr

Table des Matières