The 'Fuel' Indicator - Qlima SRE 3130 C Manuel D'utilisation

Masquer les pouces Voir aussi pour SRE 3130 C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Factory setting: switch
1 & 2 & 3 are in OFF
position (down).
air
vent
Fuel filter
M

THE 'FUEL' INDICATOR

When low on fuel level the display will show "FUEL". The heater will stop within 10-15
minutes. It will take some time after a refill before the heater is ready for use again
when the heater has used all its fuel.
N
THE 'VENT' INDICATOR
When there is insufficient ventilation in the room, an intermittent buzzer will be
heard (approximately once each 30 seconds) and the
When this signal is given, ensure that the ventilation of the room is improved (e.g.
by opening a door or window a little more), to avoid that the heater shuts off.
When the ventilation of the room is improved, the
be deactivated. When there is still insufficient ventilation, the heater shuts off
automatically. When this occurs, e -1 1 is displayed and the
blinking. After improving the ventilation of the room (e.g. by opening a door or
window a little more), the heater can be ignited by pushing the button
O
HIGH ALTITUDE ADJUSTMENT
The factory setting is for 0 – 500 meters above sea level. This setting needs to be
changed for higher altitudes to increase the blower speed and keep the combustion
correct.
Before changing the high altitude setting always remove the main's plug!
Remove the two screws beside the front panel. A small block with 4 switches on the
main electronics board becomes visible. Always leave switch 3 and 4 in the original
position.
Altitude (m)
0 - 500
501 - 1000
1001 -1500
WARNING
Never insert the mains plug when fixed front panel is not fixed!
P
MAINTENANCE
Switch off the heater, disconnect the plug from the mains and let it cool down, before
you start any maintenance work. Your heater needs hardly any maintenance. It
is, however, important that you clean the air filter and the vent filter with a vacuum
cleaner and a brush and the grid with a damp cloth, both on a weekly basis. Remove the
air filter occasionally and clean it with soapy water or with a vacuum cleaner. Prior to
reinstallation, make sure that the air filter cap has fully been dried.
indicator and buzzer will
Switch 1
Switch 2
OFF
OFF
ON
indicator will be lit.
indicator is
again.
OFF
ON
OFF
4
34