Emerson QC01 Serie Guide D'installation page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

En
12 QC04 Smart Module Intinsically safe
12.1
Product marking
Control Module
Type Label
Terminals
Fig 14. Product marking
ATEX
Hazardous or Classified Location
0344
II 1 GD Ex ia IIC T4 T80°C IP65
KEMA 02ATEX1242X
Ta = -20°C...+50°C (-4°F...122°F)
Hazardous or Classified Location
APPROVED
Intrinsically safe, Class I, II, III Div.1,
Groups ABCDEFG, T4, Type 4X/IP65
Class I, Zone 0, AEx ia IIC T4, IP65,
Ta = -20°C...+50°C (-4°F...122°F)
Hazardous or Classified Location
Intrinsically safe, Class I, II, III Div.1,
Groups ABCDEFG, T4
Ex ia IIC T4, IP65, (Class I, Zone 0/1)
Ta = -20°C...+50°C (-4°F...122°F)
DOC.IG.QC01.1 Rev.: B
12.2
ATEX Intended use
The Control Module QC04..P1.. of the FieldQ
pneumatic actuator are Group II category 1
equipment and intended for use in areas in which
explosive atmospheres caused by mixtures of air
and gases, vapours, mists or by air/dusts are likely
to occur.
The pneumatic actuator part, together with the
pneumatic Module part of the FieldQ pneumatic
actuators is a Group II category 2 equipment and
intended for use in areas in which explosive
atmospheres caused by mixtures of air and gases,
vapours, mists or by air/dusts are likely to occur.
Therefore it may be used in (ATEX) classified
Zones 1, 2 (Gasses) and/or 21, 22 (Dust).
12.3
Special conditions for safe use
(ATEX).
The material for the Control Module housing is an
aluminum alloy. When the unit is used in a
potentionally explosive atmosphere, requiring
ATEX equipment category 1 G, the unit must be
installed in such a way, that even in the event of
rare incidents, an ignition source due to impact or
friction between the enclosure and iron/steel.
For applications in explosive atmospheres caused
by air/dust mixtures and where category 1D
apparatus is required, the surface temperature has
been determined for a dust layer with a thickness
of 5 mm maximum.
12.4
Dielectric strength
Control Module QC04 complies to the dielectric
strength requirement according IEC- 60079-11
QC03 Intrinsically Safe Entity Parameters
Circuit
Terminal Ui
Power Supply
7-8
Control input
5-6
Feedback 1
3-4
Feedback 2
1-2
14
Ii
Pi
Ci
30VDC 300mA 1.2W 15 nF
30VDC 300mA 1.2W 15 nF
30VDC 300mA 1.2W 18 nF
30VDC 300mA 1.2W 18 nF
December '06
Li
0
0
0
0

Publicité