Product Failure Causes And Treatment - Advanced-Star Large Space Humidification System Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6

PRODUCT FAILURE CAUSES AND TREATMENT

-
Problem
Small mist output
No mist output
Small mist output after long
time working
Water overflow
Short distance of atomization
Mark:
When the humidifier working, should the
fog output is small, check and adjust
the floating switch to be a best working
water level--25-30mm from the
mist maker surface to the
water top.shown as
chart 6.1
Appareil électrique classe II. /
Class II electrical appliance.
Causes
1 . Improper adjustable
floating switch
2 . Unclean chamber,
contaminated water
1 . Improper adjustable floating
switch for an working water level
2 . water outlet valve is
unclosed or damaged
1 . Incrustation scale
on the surface
2 . Mist maker working overdue
to be lower efficiency
1 . Floating switch become useless
2 . Float is improper adjust and
water overflow
Dustproof net full of dust to
prevent wind blowing in
Ajust nut
Conforme aux directives CE appli-
cables
Complies with applicable EC directives
Treatment
1 . 1.Adjust the floating switch to the
best water level (chart 6.1)
2 . Clean the chamber repeatedly
1 . Adjust the cloth to the best
water level, (chart 6.1)
2 . Close/ change valve
1 . Use weak acid solution to clean
the incrustation scale repeatedly
2 . Change a new mist maker
1 . Change a new floating switch
2 . Adjust the floating switch to
the best water
Wash the dustproof net
Les appareils électriques doivent être éliminés
dans une structure de récupération
et de recyclage appropriée
Electrical appliances must be disposed of in an
appropriate collection and recycling structure
Chart 6.1