Télécharger Imprimer la page

GE Appliances YR-HQ Manuel Du Propriétaire page 5

Publicité

Les langues disponibles

Les langues disponibles

Remote Control Features and Settings
10. SWING UP/DOWN
Press the SWING UP/DOWN button to choose the
position of the horizontal airflow louvers.
Status display of air flow
COOL/DRY:
HEAT:
NOTE:
• It is advisable not to keep the vertical louver in the
downward position for an extended period of time in
COOL or DRY mode. This may cause condensate
water to form on the louver.
• When turning the unit on, the remote control will
automatically return the louver to the previous set
swing position. When turning the unit off, the louver will
rotate to the full open position prior to closing.
11. SWING SIDE/SIDE Button (select models)
Press the LOUVER SIDE/SIDE button to choose the
position of the vertical airflow louvers.
Status display of air flow
COOL/DRY/HEAT/FAN
NOTE:
• When the humidity is very high, the condensate water
may occur on the air outlet if all vertical louvers are
adjusted too far to the left or right.
• When turning the unit on, the remote control will
automatically return the louver to the previous set
position.
12. DISPLAY
Turns on and off the indoor display. Press the DISPLAY
button 10 times within 5 seconds to display the ambient
temperature. The indoor will beep 2 times when the
setting is successful. Press the DISPLAY button 10
times within 5 seconds again to display the setting
temperature. The indoor will beep 4 times when the
setting is successful.
The default display temperature is the setting
temperature.
13. SLEEP
Press the SLEEP button, the heat pump will operate the
sleep function, the display light will be turned off after 20
seconds. the control logics are as following running in
different mode.
1. COOL or DRY modes
One hour after SLEEP mode begins, the temperature
setpoint will increase 1°F (0.5°C). 2 hours after
beginning sleep mode the setpoint will increase 1°F
(0.5°C). Seven hours after beginning sleep mode,
the setpoint will decrease 1°F (0.5°C). At the eighth
hour the unit will be back to the original setpoint. This
feature helps with achieving maximum efficiency and
comfort while you sleep. See the image below.
SLEEP operation starts
Rises 1℉
Rises 1℉
temp.setting
1h
2h
In COOL, DRY mode
49-5000491 Rev. 0
Decrease 1℉
Decrease 1℉
Unit stop
7h
8h
2. Heat Mode
One hour after SLEEP mode starts, the setting
temperature will decrease 2°F. After 2 hours later, the
setting temperature will decrease additional 2°F. after
5 hours,the setting temperature will increase 1°F, after
8 hours, the unit will run according to the initial setting
temperature, this feature helps with achieving maximum
efficiency and comfort the your feeling while you sleep.
SLEEP operation starts
temp.setting
Decrease 2℉
1h
2h
3. AUTO mode
The unit operates in corresponding sleep mode
adapted to the automatically selected operation mode.
NOTE:
When the unit is set to sleep mode, the fan speed
will be set to low speed and cannot be changed.
When the TIMER function is set, the sleeping
function cannot be set. If the sleeping function has
been set and the user sets the TIMER function, the
sleeping function will be canceled and the unit will
be set to the timer function.
14. FOLLOW
Press the FOLLOW button, the air will follow the body no
matter people stand or moving. See chart below.
Model
Detect Area
FOLLOW Detect person
in single zone
Detect person
in multi zones
Detect
nobody
15. SURROUND
Press the SURROUND button. The air will surround the
body no matter whether people are standing or moving.
See chart below.
Model
Detect Area
SURROUND Detect
person in
single zone
Detect
person in
multi zones
Detect
nobody
Decrease 2℉
Rises 1℉
7h
8h
In HEAT mode
Louver Up/
Louver Left/
Down
Right
Remote setting
Swing in the
position
direction of the
person
Remote setting
Swing
position
automatically
Keep the initial
Keep the initial
setting position
settings position
Louver Up/
Louver Left/
Down
Right
Remote
Keep the initial
setting
setting position
position
"Health airflow
Swing
(up) in cooling
automatically
mode
Health airflow
(down) in
heating mode"
Keep the
Keep the
initial settings
initial settings
position
position
5

Publicité

loading

Ce manuel est également adapté pour:

Wj26x26497