1) Verify that the correct filter is installed for wet or dry vacuuming and the container latches are
secured.
2) Secure the locking end of the hose into the vacuum suction port.
3) Push the desired accessories onto the hose nozzle. The air flow regulation allows you to
change vacuum cleaner suction. For best cleaning results, fully close the air flow regulation (Fig. 8).
4) Plug the power cord into a power outlet.
5) Turn on the motor by assigning the switch to the "I" ON position.
6) Once you have completed vacuuming, switch to the "O" OFF position and unplug the power
cord from the power.
For Dry Vacuuming:
WARNING:
CLEANER FILTER, ENSURE THAT THE POWER CORD IS UNPLUGGED AND
SWITCHED OFF.
1) To prepare your vacuum cleaner for dry vacuuming, install the cartridge filter over the filter cage
with the flat end of the filter towards the vacuum power head. Carefully push filter until it sits
flush forming a tight seal.
2) Place the filter retainer cap on top of cartridge filter over the raised lip and tighten the retainer
lock clockwise to secure against the internal filter cage (Fig. 9).
3) Place the pre-filter on the collection tank. The pre-filter is deigned to cover the full circumference
of the tank. Replace the power head, and secure it in place (Fig. 10).
4) Optionally, fully fit the dust bag flange onto the inlet stub. The Vacuum cleaner can we be used
with or without dust bags.
IMPORTANT: Check the filter regular for optimal performance. An old or blocked filter will reduce
suction performance.
For Wet Vacuuming:
1) To prepare your vacuum cleaner for wet vacuuming, remove the retainer cap and the dry use
cartridge filter and pre-filter.
2) Carefully install the supplied foam filter over the internal filter cage, making sure the whole cage
is covered (Fig. 11).
WARNING:
DO NOT USE THE CARTRIDGE FILTER FOR WET VACUUMING.
DO NOT USE A DUST COLLECTION BAG FOR WET VACUUMING.
DO NOT USE THE PRE-FILTER FOR LIQUID VACUUMING.
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle
completely; leave a gap at the tip of the nozzle to allow air inflow. The machine is fitted
with a float valve that stops the suction action when the container reaches its maximum
capacity. You will notice an increase in motor noise. When this happens, turn off the
machine, disconnect from power supply, and drain the liquid using the drainage hose.
Ensure the drainage cap is re-installed before continuing to vacuum.
BEFORE INSTALLING, REMOVING OR CLEANING THE VACUUM