DSC WS4936 Instructions D'installation Et D'utilisation page 2

Détecteur de fumée sans fil
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Status
LEDs
Heat Test
Red flash every second
Smoke
Red flash every second
Alarm
Smoke Test
Red flash every second
Test Alarm
Red flash every second
Detector
Yellow flash every 4 seconds
Trouble
Low Battery
Yellow flash every 12 seconds
Detector
Yellow flash every 8 seconds
Dirty
Power-up
Red, yellow, green, flash sequence
Red, yellow, green flash sequence
Tamper
every 12 seconds
Table 1: Detector and Status Indication
Detector Dirty Feature
When the detector has been contaminated, the yellow LED blinks once every 8 seconds and there
is a chirp every 48 seconds. Refer to the MAINTENANCE section for cleaning the detector. After 12
hours, the panel will display a loss of supervision message.
Heat Alarm
The heat detector (cULus versions only) will go into alarm when the heat signal level exceeds the
heat alarm threshold (135ºF/57ºC); and will automatically restore when the heat signal level falls
below the heat alarm threshold (restore). The detector will also go into heat alarm if there is a rapid
Sounder
ANSI S3.41 temporal 3
ANSI S3.41 temporal 3
(press button to hush for 5-10 minutes)
ANSI S3.41 temporal 3
(press button to hush for 5-10 minutes)
ANSI S3.41 temporal 3
One chirp every 48 seconds
One chirp every 48 seconds (press button to
hush for 12 hours)
One chirp every 48 seconds
One chirp after power-up sequence
Off
increase in the temperature over a short period of time. During an alarm the LED will flash 1/second
and the sounder will sound the evacuation temporal pattern.
Tamper
The removal of the detector from the mounting plate initiates a "tamper" transmission. The tamper
condition is restored after the detector is mounted on the plate.
Wireless Transmissions
A supervisory message is transmitted to the control panel at 64-minute intervals for the WS4936
and 12-minute intervals for the WS4936EU/WS8936 models. If the signal is not received the control
panel determines that the detector is missing. The detector transmits the following:
Alarm / Alarm Restore - (heat or smoke alarm). Transmitted at time of occurrence.
l
Tamper / Tamper Restore - (tamper switch activated) 10 second maximum delay on restore
l
before transmission.
Low Battery - (battery voltage falls below threshold). Battery voltage is tested & transmitted at
l
the time of supervisory or other transmissions.
Trouble - (detector fault or sensor compensation limit reached). Troubles are transmitted at the
l
time of occurrence.
Batteries
NOTE: The batteries must be replaced by service persons only.
The wireless smoke and heat alarm is powered by 3 AAA batteries. Use Duracell Procell PC2400
or Energizer E92 for the WS4936. Use Duracell Procell MN2400 for the WS4936EU/WS8936.
Expected battery life is 3 years under typical use. Note: Battery life past 1 year not verified by
UL/ULC. The detector regularly checks for a low battery. If a low battery is detected, the transmitter
sends a low battery message to the control panel, which displays the detector's ID at low battery. In
addition, the yellow LED of the detector will blink every 12 seconds. The detector's sounder will
chirp every 48 seconds (yellow LED continues to blink) until the batteries are replaced. Pressing the
hush button will silence the chirps for 12 hours, if no other trouble conditions exist. The batteries
should be replaced when the chirps begin. Replace the batteries with new ones.
Battery Installation and Replacement
To replace batteries:
1. Remove the detector from its mounting base by twisting the detector counterclockwise. Care-
fully remove batteries by lifting from the "+" end using a flathead screwdriver and dispose of
them according to local regulations.
2. To ensure a proper power-down sequence, wait a minimum of 20 seconds before installing
new batteries.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ws4936eu

Table des Matières