Specifications; Hydraulic Schematic - Greenlee AML Serie Manuel De L'utilisateur

Perceuse hydraulique à percussion rotative
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications

Hydraulic Rotary Impact Drill
Type of Hydraulic System ....................... Open-Center or
Hydraulic Pressure Port .............3/4–16 SAE O-ring Boss
Hydraulic Tank Port ...................3/4–16 SAE O-ring Boss
Bits
SDS Plus Type Chuck ................ SDS Plus Type Shank
Noise Levels
Sound Power Level (maximum) ..........................85 L
Mass/Weight ................................................ 4.1 kg (9 lbs)
Length ..................................................... 285 mm (11.2")
Width ........................................................... 89 mm (3.5")
Height ...................................................... 280 mm (11.0")
Output
Revolutions per Minute @ 18.9 l/min (5 gpm) .........900
Revolutions per Minute @ 22.7 l/min (6 gpm) .......1050
Impacts per Minute @ 22.7 l/min (6 gpm) .............5400
Max. Single Impact Energy ................................... 2.4 J
Drilling Capacity
Concrete ................................................... 22 mm (7/8")
Steel ......................................................... 13 mm (1/2")
Wood .....................................................30 mm (1-1/8")
Core Bit .................................................68 mm (2-5/8")
Hydraulic Power Source
Do not exceed the following hydraulic power source
maximums:
• Hydraulic flow: 45.4 l/min (12 gpm)
• Pressure relief setting: 138 bar (2000 psi)
• Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Type of Hydraulic System ........................ Open-Center or
Flow
Minimum ..........................................15.1 l/min (4 gpm)
Recommended .................................22.7 l/min (6 gpm)
Maximum .......................................45.4 l/min (12 gpm)
Greenlee Tools, Inc.
Pressure Relief Setting
Minimum ......................................... 68.9 bar (1000 psi)
Closed-Center
Maximum ......................................... 138 bar (2000 psi)
Filtration ............................................ 10 micron (nominal)
Back Pressure (maximum)* .................. 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure
for the HTMA (Hydraulic Tool Manufacturers Association).
Greenlee tool will operate satisfactorily at this standard.
1. Maximum hydraulic fluid temperature must not
WA
exceed 60 °C (140 °F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
2. Hydraulic flow must not exceed 45.4 l/min (12 gpm).
Install a flow meter in the return line to measure the
rate of hydraulic flow before using the tool.
3. Pressure relief valve setting must not exceed
138 bar (2000 psi) at your tool's maximum flow.
Locate the pressure relief valve in the supply circuit
to limit excessive hydraulic pressure to the tool.

Hydraulic Schematic

Recommended Hydraulic Fluids
Use any non-detergent, petroleum-based hydraulic
fluid which meets the following specifications or HTMA
specifications.
S.U.S. @:
38 °C (100 °F) ...............................................140 to 225
99 °C (210 °F) ............................................ 40 minimum
Flash Point ................................170 °C (340 °F) minimum
Closed-Center
Pour Point ..................................-34 °C (-30 °F) minimum
7
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
Hydraulic Rotary Impact Drill
FILTER
(10 MICRON)
RELIEF
VALVE
138 bar
RESERVOIR
(2000 psi)
CONTROL
VALVE
FLOW METER
PUMP
POWER SOURCE
COOLER
T
TOOL
P

Publicité