• The meter provides DC current measuring ranges as follows: 60μA, 6mA,60.00mA, 600.0mA and
10.00A; and AC current measuring ranges: 60.00mA, 600.0mA, and 10.00A.
• Measurement of current:
1. Turn the rotary switch to the appropriate position.
2. Connect the test lead in black to COM input socket. Connect the test lead in red to a mA input
socket when the measured current is less than 600mA; connect the test lead in red to a 10A input
socket when the measured current is 600mA~10A.
3. Disconnection of the circuit to be measured Connect the test lead in black to the end of disconnected
circuit (the voltage is lower) and connect the test lead in red to the end of the disconnected
circuit (voltage is higher).
4. Connect the power to the circuit and capture the displayed reading. If the display unit only shows
"OL", it means the input is over the selected measuring range. At this moment, turn the rotary switch
to a higher measuring range.
3.2.8 NCV test (non-contact voltage detection)
Turn the rotary switch to NCV position, and place the top of the meter approach the conductor. If
the meter detects the AC voltage, the indicators for signal density (high, medium and low) will be on
in accordance with the detected density, while the beeper will sounds alarms at different frequencies.
Note:
1. Voltage may still remain in the absence of any indication. The operator shall not rely on non-contact
voltage detector to check the presence of voltage. The detection operation may be affected by
various factors, including socket design, insulation thickness and type.
2. When the voltage is input into the meter's input terminal, the voltage sensor LED may be on as a
result of induced voltage.
3. External sources of interference (like flashlight and motor) may trigger non-contact voltage detection.
3.2.9 Live line test
1. Turn the rotary switch to the position Live.
2. Connect the test lead in red to Live input socket.
3. When a single test lead is inserted into jack L of power socket or approaches a live conductor, if
the meter detects AC voltage, the meter's indicator for the intensity (high, medium and low) of
induced voltage signal will be on and the beeper sounds alarms for different intensities.
3.2.10 Measuring temperature(depends on different model,only for the meter with it)
Put the range switch at the gear of ℃/℉. Insert the red plug of the thermocouple into the end of ℃,
and insert the black plug of the thermocouple into COM socket. Directly read the temperature
value from the display screen after the reading is stable.
Notes: The maximum measuring temperature for the K-type thermocouple dispatched at random is
250 ℃, and its instant measuring value can reach 300
℃.