WIRING CONNECTIONS (BUILT-IN UNITS)
NOTE: Wire strain relief adapter supplied loose is for connecting to rigid metallic conduit.
For flexible conduit or power cords, an approved strain relief fitting must be supplied by others.
1.
Remove control panel to access terminal block.
2.
Knock out the appropriate hole plug located on enclosure panel and connect conduit strain relief.
Thread supply leads through strain relief and connect power leads to terminals marked "L1", "L2"
3.
and "L3"; and, the neutral lead to terminal marked "N".
4.
Connect ground lead (green with yellow stripe) to ground lug marked "
5.
Secure all connections, tighten strain relief and reinstall cover panel.
Locate equal potential grounding screw positioned on control enclosure marked "
6.
Remove screw and secure an appropriate grounding wire terminal.
4
".
".