EUROPEAN INSTALLATION INSTRUCTIONS
IMPORTANT!
These installation instructions are prepared for personnel authorized, qualified, certified or
licensed to install electrical equipment, who should perform the initial startup and adjustments.
IMPORTANT!
Verify that the incoming voltage is the same as that for which the unit is rated. An electrical
plate specifying rated voltage, wattage, frequency and phase is affixed to the appliance.
Connecting units to greater voltage than their rating may cause severe damage to equipment
components.
Connecting units to voltage less than their rating will result in decreased performance.
IMPORTANT! (BUILT-IN APPLIANCES)
An approved all pole power disconnect switch, with at least 3mm contact gap, must be
supplied and installed in the fixed wiring in an accessible location (close proximity to the
appliance) by a licensed electrician. Refer to equipment name plate for electrical ratings.
IMPORTANT!
All built-in appliances must be installed according to instructions on the GLD (General Layout Data)
sheet included with the unit.
SUPPLY CORDS
Supply cords, supplied by the installer, shall be oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other elastic-sheathed cord (code designation 245 IEC 57) or
an approved metallic conduit connection.
Supply cords must not exceed 2m length between the point where the cord enters the
appliance and the entry to the outlet box.
MINIMUM CROSS-SECTIONAL AREA OF CONDUCTORS
Supply power wire size for griddle models G-13EU, PG-13EU, G-136EU and PG-136EU must
G-13
2
be 1.5 mm
minimum.
Supply power wire size for all griddle models G-19EU, PG-19EU, G-196EU and PG-196EU
G-19
must be 2.5 mm
Supply power wire size for all griddle models G-23EU, PG-23EU, G-236EU and PG-236EU
G-23
must be 4.0 mm
Supply power wire size for all griddle models G-24EU, PG-24EU, G-246EU and PG-246EU
G-24
must be 10.0 mm
2
minimum.
2
minimum.
2
minimum.