1. Transmission losses

Sometimes transmission losses may arise, indicated by missing
temperature data in the sensor's curve display.
Data losses may be caused by:
1.

Problems inside the USB-receiver

2.
Problems in the temperature sensor module
3.
Problems in the signal transfer between temperature sensor
module and USB-receiver
1.1. Problems inside the USB-receiver
The receiver does not registrate a single data signal, even if the sensor
is located at a minimum distance to the receiver.
Potential problems:
-
USB-cable between receiver and computer is missing or defect
-
Improper installation of the USB-module
-
Unknown software problem in the computer system
Internal battery BS-510 is empty
-
(replace the battery)
Suggested solutions:
-
Check the display window in the temperature logger display
for a field in the lower left area. The field is to display the value
'ready' continously. If the display intermittently displays
'RF_USB-Communication failure', the Windows operating
system failed to find the USB-module.
-
Remove the USB-cable, wait about ten seconds and reconnect
the cable.
-
Deinstall the temperature logger application software and
reinstall it again.
Please check the internal BS-510 clock battery (Type CR2032)
The lifetime of the BS-510 battery is about 5 years!