Milnor E-P Plus Manuel D'utilisation page 10

Masquer les pouces Voir aussi pour E-P Plus:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Normal Operation—E-P Plus,
M-Style Washer-Extractor
Open the door.
Safeguards prevent the door from opening while a formula is in progress and
immediately after manually terminating a formula. Press the door latch.
Unload the Machine.
Monitor Normal Operation
When the door is closed, normal run displays similar to those below will appear.
Level not satisfied; no
chemicals actuated:
Level satisfied; no
chemicals actuated:
Chemicals or signal
actuated:
Draining:
Extracting:
Data
What it Means
23:04 Formula time remaining
F02
Formula number
S01
Step number
HC3
Water valves on: Hot, Cold, 3rd
dF/dC Bath temperature (°F/°C) if temp
probes configured; A=achieved,
D=desired
01:00 Drain time remaining
05:35 Extract time remaining
23:04 F02S01
02:30
dF=A168/D170
LEV 2
23:00 F02S01
02:05
dF=A168/D170
LEV 2
21:10 F02S01
01:19
INJECT CHEM 1 & 2
12:23 F02S02
01:00
DRAINING TO SEWER
05:35 F02S05
05:35
FINAL EXTRACT
Bath Steps
STEP 01
02:30
CHEM 1 & 2
SPD 0
LEV 2
Drain/Extract Steps
DRAINING TO SEWER
6
MSOUJMNOAE/9433AV (3 / 3)
23:04 STEP 01 02:30
alternates
WAIT FOR LEVEL 2 HC3
with
23:00 STEP 01 02:05
alternates
dF=A168/D170
with
21:10 STEP 01 01:19
alternates
dF=A168/D170
with
12:23 DRAINING 01:00
alternates
DRAINING TO SEWER
with
05:35 EXTRACT
alternates
FINAL EXTRACT
with
Data
What it Means
Step name
Step time remaining
Chemical(s) injected
If speed is programmable:
0=low, 1=high
Level desired: 1, 2
Step description
SPD 1
LEV 2
05:35