Connecting Gas Dryers - KENMORE ELITE 796.8107 Série Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

CONNECTING GAS DRYERS

GAS REQUIREMENTS (GAS MODELS ONLY)
WARNING:
electric shock, or injury to persons when using this
appliance, follow basic precautions, including
the following:
• Gas supply requirements: As shipped from the
factory, this dryer is configured for use with natural
gas (NG). It can be converted for use with propane
(LP) gas. Gas pressure must not exceed 8 inches
(20 cm) water column for (NG), or 13 inches (33 cm)
water column for (LP).
• A qualified service or gas company technician must
connect the dryer to the gas service. Failure to follow
these instructions can result in fire, explosion, or death.
• Isolate the dryer from the gas supply system by
closing its individual manual shutoff valve during any
pressure testing of the gas supply. Failure to do so can
result in fire, explosion, or death.
• Supply line requirements: Your laundry room must
have a rigid gas supply line to your dryer. In the
United States, an individual manual shutoff valve
MUST be installed within at least 6 ft. (1.8 m) of the
dryer, in accordance with the National Fuel Gas Code
ANSI Z223.1 or Canadian gas installation code CSA
B149.1. A ⅛ inch (3 mm) NPT pipe plug must be
installed. Failure to do so can result in fire, explosion,
or death.
• If using a rigid pipe, the rigid pipe should be ½ inch
(12.7 mm) IPS. If acceptable under local codes and
ordinances and when acceptable to your gas supplier,
⅜ inch (9 mm) approved tubing may be used where
lengths are less than 20 ft. (6.1 m). Larger tubing
should be used for lengths in excess of 20 ft. (6.1 m).
Failure to do so can result in fire, explosion, or death.
ELECTRICAL REQUIREMENTS FOR
GAS MODELS ONLY
• Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord. Failure
to follow this warning can result in fire, explosion, or
death.
• For personal safety, this dryer must be properly
grounded. Failure to follow this warning can result in
fire, explosion, or death.
WARNING
ELECTRIC SHOCK HAZARD
Failure to follow safety warnings could result in seri-
ous injury or death.
This dryer is equipped with a three-prong grounding
plug for protection against shock hazard and should
be plugged directly into a properly grounded three-
prong receptacle. Do not cut or remove the ground-
ing prong from this plug.
* Do not use extension cords.
To reduce the risk of fire,
• Connect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in fire,
explosion, or death.
• To prevent contamination of the gas valve, purge the
gas supply of air and sediment before connecting
the gas supply to the dryer. Before tightening the
connection between the gas supply and the dryer,
purge remaining air until the odor of gas is detected.
Failure to do so can result in fire, explosion, or death.
• DO NOT use an open flame to inspect for gas leaks.
Use a noncorrosive leak detection fluid. Failure to do
so can result in fire, explosion, or death.
• Use only a new AGA- or CSA-certified gas supply
line with flexible stainless steel connectors. Failure to
do so can result in fire, explosion, or death.
• Securely tighten all gas connections. Failure to do so
can result in fire, explosion, or death.
• Use Teflon tape or a pipe-joint compound that is
insoluble in propane (LP) gas on all pipe threads.
Failure to do so can result in fire, explosion,
or death.
• DO NOT attempt any disassembly of the dryer;
disassembly requires the attention and tools of
an authorized and qualified service technician or
company. Failure to follow this warning can result in fire,
explosion, or death.
• This dryer must be plugged into a 120-VAC, 60-Hz.
grounded outlet protected by a 15-ampere fuse or
circuit breaker. Failure to follow this warning can result
in fire, explosion, or death.
• Where a standard 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded 3-prong
wall outlet. Failure to follow this warning can result in
fire, explosion, or death.
3-prong
grounding
type wall
receptacle
3-prong
grounding
plug
10
Ensure proper
ground exists
before use.