MAS−...
7
Operation
Please note
Extreme conditions reduce the service life
of the MAS−... .
S Take into account the fact that the fol
lowing factors can considerably reduce
the service life C (see diagram Fig. 12):
increasing contracton h and
additional increasing mass m,
increasing ambient or operating
temperatures.
The compression heat produced during
operation can be reduced with bilateral
pressurization (flushing) (only with
MAS−...−MO..).
Check the MAS−... for signs of aging at the following intervals.
S
Check
interval
Every 500,000
strokes
*)
The test intervals are reduced under extreme ambient conditions (e.g. strong
sunlight, high humidity, high ozone concentration).
Fig. 13
Festo MAS−... 0401b − English
Test
*)
Visible Test
Audible test
Fig. 12
Possible sign of aging
Clamping cracks,
blistering, other damage
to surface
Textile fibre worn
Air can be heard escaping
Measure to be taken
Replace the MAS−...
Check pneumatic connec
tion / replace the MAS−...
21