AL2
AL1
(*)
alarm 1
alarm 2
For AL1 = reverse absolute alarm (low) with positive Hyst1, AL1 t = 1
(*) = OFF if disabled on power-up
For AL2 = direct absolute alarm (high) with negative Hyst2, AL2 t = 0
SP+AL1
SP
reverse
alarm
direct
alarm
For AL1 = Lo deviation alarm with negative Hyst 1, AL1 t = 3
For AL1 = Hi deviation alarm with negative Hyst 1, AL1 t = 2
22
User
U.CA
calibration
Default: 0
(1)
The analog output in 20mA is calibrated with accuracy higher than 0.2 % f.s.; calibrate when
converting to 10V output.
(2)
In the absence of calibration, accuracy is higher than 1% f.s.; calibrate only if higher
accuracy is required.
Normal absolute alarm
AL2 + Hyst2
AL1 + Hyst1
time
Deviation alarm
Hyst1
time
U.CAL menu
Val
Function
1
Analogue output
2
Input 1 – custom 10V / 20mA
3
Input 1 - custom 60mV
4
Custom PT100 / J PT100
5
Custom PTC
6
Custom NTC
7
Input 2 - custom TA (2)
ALARMS
AL1
reverse alarm
direct alarm
For AL1 = symmetrical Lo absolute alarm with Hyst1, AL1 t = 5
For AL1 = symmetrical Hi absolute alarm with Hyst1, AL1 t = 4
* Minimum hysteresis = 2 scale points
SP+AL1
SP
SP-AL1
reverse alarm
direct alarm
For AL1 = Symmetrical Lo deviation alarm with Hyst 1, AL1 t = 7
For AL1 = Symmetrical Hi deviation alarm with Hyst 1, AL1 t = 6
(1)
Symmetrical absolute alarm
Symmetrical deviation Alarm
AL1 + [ Hyst1 * ]
AL1 - [ Hyst1* ]
time
time
22