Télécharger Imprimer la page

For Hook-Up; Air Supply; Air Hose Requirements - CH CHN50300 Instructions D'utilisation

Cloueuse / agrafeuse de plancher pneumatique

Publicité

Les langues disponibles

Les langues disponibles

Set-Up (Continued)
MINIMuM CoMPoNeNtS requIred For Hook-uP
AIR COMPRESSOR: The air compressor must be able to maintain a minimum of 70 psi
when the nailer is being used. An inadequate air supply can cause a loss of power and
inconsistent driving. See Chart 2.
PRESSURE REGULATOR: A pressure regulator is required to control the operating
pressure of the nailer between 70 psi and 90 psi.
AIR SUPPLY HOSE: ALWAYS use air supply hoses with a minimum working pressure
rating equal to or greater than the pressure from the power source, or 150 psi,
whichever is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 3/8 inch air hoses
for 50 ft. run or longer (see Figure 14 and Chart 3).
Hook-uP INStruCtIoNS For NaIler to aIr SuPPly
Figure 13 shows the recommended hookup for the nailer.
NOTE: For better performance, install a 3/8 inch quick plug (1/4 inch NPT threads) with
an inside diameter of .315 inch (8 mm) on the nailer and a 3/8 inch quick coupler on the
air hose.
1. With ON/OFF switch in OFF position, plug compressor into electrical outlet.
2. Close pressure regulator by turning all the way to the left. Turn compressor ON and
let it pump all the way up to automatic shut-off pressure.
3. Attach air hose to regulator outlet. Adjust pressure regulator by turning to the right
so that outlet pressure is between 70 psi to 90 psi.
4. Nailer requires lubrication before each use. Place 4-5 drops of 30 weight non-
detergent oil in nailer at air inlet. It helps to tip nailer back in order to add oil (See
Lubrication section on page 10).
5. Pull rubber bumper on nailer into UP position (see Figure 15).
6. Load fasteners into nailer (See Loading/Unloading the Nailer section on page 12).
Follow flooring manufacturer's recommendation regarding length and type of
fastener.
7. Point the nailer in a safe direction while attaching to air hose.
8. Nailer is ready for use. May need to adjust outlet pressure to achieve proper
fastener depth. See page 14 for Fastener Depth and Placement.
Outlet
Pressure
Tank
Gauge
Pressure
Gauge
Regulator
Figure 13 - recommended Hookup
Regulator
Quick
Outlet
Coupler
Quick
Coupler
Quick
Plug
Air
Hose
70 psi Minimum
90 psi Maximum
Chart 2
Rated 150 psi or greater
Interior Diameter
Figure 1 - air Hose requirements

aIr HoSe requIreMeNtS

DIAMETER
LENGTH OF RUN
1/4 inch
Less than 50 feet
3/8 inch
Greater than or equal
to 50 feet
Chart 3
Rubber Bumper
Rubber Bumper in
in the DOWN
the UP position
position
Figure 15 - attach air hose with rubber
bumper in uP position
Quick
Plug
www.chpower.com
CHN50300
11

Publicité

loading