Wiring

WARNING
(NEC).
Pump MUST be permanently connected to circuit. If other lights or appliances are also on the same circuit, be sure
to add their amp loads before calculating wire and circuit breaker sizes. Use the load circuit breaker as the Master
On-Off switch.
WARNING
off before working on wiring, wiring connections, or motor. Re-install the motor end cover and all other
wiring covers before turning on the power. Reference motor data plate for proper wiring information.
To Wire a Single Speed, Single Voltage Motor
1. Turn off power.
2. Remove the motor end cover.
3. There are two terminals labeled L1 and L2. Attach the power leads to these terminals. Either wire may attach to
either terminal.
4. Reinstall motor end cover.
WARNING
– If you do not use conduit when wiring motor, be sure to seal wire opening on end of motor to
prevent dirt, bugs, etc., from entering.
4. Startup & Operation

Prior to Start-Up

If it is necessary to perform a water pressure test prior to initial use to ensure plumbing system is functioning
properly, then the following criteria should be maintained for this test:
1.
Have a professional perform this test.
2. Ensure all Hayward pump and system components are removed from system prior to performing test.
WARNING
– If circulation equipment must remain in the plumbing system during water pressure test, do not
apply more than 10 psi pressure to the system. Be sure water pressure has been released, using the filter manual air
relief valve, before removing pump strainer cover.
WARNING
Separation Hazard
valve (if available) on filter, when starting the circulating pump system. Failure to do so could result in severe
personal injury.

Starting/Priming the Pump

Rotate strainer cover counter clockwise to remove. Fill strainer housing with water to suction pipe level. Replace
strainer cover, rotate clockwise and hand tighten. If water leakage occurs from anywhere on the pump or filter, DO
NOT start the pump. If no leakage occurs, stand at least 10 feet from pump and/or filter and proceed with starting
the pump.
– All electrical wiring MUST conform to local codes, regulations and the National Electric Code
Risk of dangerous or fatal electrical shock
All suction and discharge valves MUST be OPEN, as well as filter air relief
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
. Be sure that power to the motor circuit is