INSTALLATION MANUAL PURE | PART I | P1528 REV C
INSTRUCTIONS
GENERAL VENTILATION
GUIDELINES:
•
All Sunshower appliances must
be installed with ventilation
ducts
•
Ventilation feed and exhaust
can both be a maximum of 3 m
•
The space from which/to which
ventilation is provided must be
at least 12 m
3
•
The ducts can be of any
material, with dimensions Ø100
mm or 110 * 55 mm
•
Make as few bends as possible
in the ducts
•
The Sunshower may not be
connected to an existing
ventilation system
NON-RETURN VALVES:
Non-return valves must be
installed if the air for your
Sunshower is extracted from a
humid area, e.g. from the outside
or from the bathroom. Please
refer to the image and subsequent
pages for instructions. The non-
return valves can be ordered
additionally (as a set with the
glass panels) or can be purchased
separately at your hardware store.
Examples of humid areas:
bathroom, outside.
Examples of dry areas:
bedroom, hallway, toilet.