Geberit Bambini Manuel D'utilisation page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Rectifying malfunctions
Malfunction
Cause
Tap aerator contaminated
Water jet too
weak.
Basket filter blocked
Pipe pressure too low
Pipe pressure too low
Network failure
Flush does not
actuate.
Battery dead
Technical fault
Water runs
Technical fault
continuously.
IR window is dirty or wet
Unwanted flow of
IR window scratched
water, either too
Detection distance of the IR sensor
soon or delayed.
not set correctly
Water drips from
Technical fault
the tap housing.
Red LED flashes
during flush
Battery almost dead
actuation.
LED lights up,
flush does not
Battery dead
actuate.
9007203497796235-1 © 06-2018
968.598.00.0 (00)
Rectification
▶ Clean the tap aerator. → See
"Cleaning the tap aerator",
page 17
▶ Clean the basket filter. → See
"Cleaning the basket filter",
page 17
▶ Contact a skilled person.
▶ Contact a skilled person.
▶ Check the power supply.
▶ Replace the battery. → See
"Replacing the battery",
page 19
▶ Contact a skilled person.
▶ Shut off water supply and
contact a skilled person.
▶ Clean or dry the IR window.
▶ Contact a skilled person.
▶ Set detection range. → See
"Setting the detection distance of
the IR sensor", page 18
▶ Shut off water supply and
contact a skilled person.
▶ Replace the battery. → See
"Replacing the battery",
page 19
▶ Replace the battery. → See
"Replacing the battery",
page 19
EN
15

Publicité

Table des Matières
loading

Table des Matières