Troubleshooting
Fault
The aspirator does not have
much extraction power
Dust leaks from the vacuum
cleaner
Electrostatic current on the
vacuum cleaner d
Causes
Clogged primary filter
Clogged suction pipe
Insufficient air
The filter is torn
Inadequate filter
Non existent or inefficient
earthing
-29-
Tutti i diritti riservati / All rights reserved
Tous droits réservés / Alle Rechte vorbehalten
Remedies
Shake the filter. Replace it if
this is not sufficient
Check the suction pipe and
clean it
Increase the inlet air pres-
sure
Make sure that the pressure
in the air main is adequate
Change it for another of identi-
cal category
Change it for another of suit-
able category and check
Make sure that the machine
has been correctly groun-
ded
It is essential for the suction pipe
to be of the antistatic type (only
Atex versions)