Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the
for CFM restrictions.
By default the maximum blower CFM is set to 600.
!
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
To enable ACT
1. Before hood installation, gain access to PC board by following the steps shown in FIG. J.
2. Change plastic jumper positioning as shown in FIG. K to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled ACT
max. 3 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower CFM.
Models: ZAZ, ZLC, ZRM, ZRE
- Locate PC board box on top of blower housing.
- Remove 2 to 4 screws attaching PC board cover.
FIG. J
7
8
7
5
6
3
4
1
2
5
3
1
J u m p e r
Max. Blower CFM
PC Board
20
www.zephyronline.com
Jumper Pins
Plastic
7
8
Jumper
5
6
3
4
1
2
J u m p e r
5 - 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
8
7
8
6
5
6
4
3
4
2
1
2
3 - 4
J u m p e r
1 - 2
Max. Blower CFM
390
290
FIG. K

Publicité

Table des Matières
loading

Table des Matières