Electrical Connection - Samsung NQ70-5-D Serie Manuel D'installation

Masquer les pouces Voir aussi pour NQ70-5-D Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation instructions
10 English
Install_NQ5300R_NQ70R5511DG_AA_DG68-01149A-04_EN.indd 10
4.
Lower the oven door to the fully open
position. If the oven door does not open
to a full 90°, repeat steps 1 through 3.
5.
Locate the oven door hinge locks in the
corners of the oven door, and rotate the
hinge locks toward the oven cavity to
the locked position.
See Step 1 (illustration A) in the
"Remove Oven Door" section for proper
locked position.
6.
Close the oven door.
7.
When the hinges are properly installed
and the door closed, there should be
an even gap between upper and lower
door. If one side of the oven door is
hanging lower than the other, the hinge
on that side is not properly installed.
8.
Connect Wire Harness.

Electrical connection

For Combi. Ovens
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Make sure to ground the oven.
Failure to follow these instructions can result in death, fire, or electrical shock.
This oven is manufactured with a neutral (white) power supply wire and a cabinet-
connected ground (green or bare) wire twisted together.
1.
2.
A
3.
4.
A.
UL listed or CSA approved
5.
conduit connector
6.
7.
Disconnect power.
Feed the flexible conduit from the oven
through the opening in the cabinet.
Remove junction box cover if it is
present.
Install a UL listed or CSA approved
conduit connector to the junction box.
Route the flexible conduit from the
oven to the junction box through a
UL listed or CSA approved conduit
connector.
Tighten screws on conduit connector.
See "Electrical Connection Options
Chart" to complete installation for your
type of electrical connection.
11/11/2019 6:07:31 PM